modelLightsAreaSpecific
Heat flow due to lighting relative to room area and specific lighting power
Extends from BaseClasses.PartialInternalGain.
Information
Overview
Heat source with convective and radiative component. The load is determined by multiplying a schedule (input 0..1) and a specific thermal power and the room's area.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.Area | roomArea | Area of room | |
| Real | lightingPowerRoomAreaSpecific | 10 | Lighting power per square meter room |
| Modelica.Units.SI.Area | areaSurfaceLightsTotal | 0.01*roomArea | Surface of all lights in the room |
Revisions
-
March 30, 2020 by Philipp Mehrfeld:
#886: Summarize models to partial model. Make all models dependant from a relative input 0..1. Many refactorings. -
October 21, 2014 by Ana Constantin:
Added a lower positive limit to the surface area, so it will not lead to a division by zero -
Mai 19, 2014 by Ana Constantin:
Uses components from MSL and respects the naming conventions -
May 07, 2013 by Ole Odendahl:
Added documentation and formatted appropriately