modelMachinesRelToMaxValue
Multiplies relative input with max value (heat flow due to machines in W)
Extends from BaseClasses.PartialInternalGain.
Information
Overview
Heat source with convective and radiative component. The load is determined by a relative input which is multiplied with a maximal power.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.Area | areaSurfaceMachinesTotal | 0.02*maxHeatFlowAbsolute | Total surface area of all machines (radiative heat source) (for a room in a single-family hous e.g. 2 m2) |
| Modelica.Units.SI.HeatFlowRate | maxHeatFlowAbsolute | Maximal absolute heat flow of machines |
Revisions
-
March 30, 2020 by Philipp Mehrfeld:
#886: Summarize models to partial model. Make all models dependant from a relative input 0..1. Many refactorings. -
October 21, 2014 by Ana Constantin:
Added a lower positive limit to the surface area, so it will not lead to a division by zero -
Mai 19, 2014 by Ana Constantin:
Uses components from MSL and respects the naming conventions -
May 07, 2013 by Ole Odendahl:
Added documentation and formatted appropriately