blockCheckDryBulbTemperature

Check the validity of the dry bulb temperature data

Extends from Modelica.Blocks.Icons.Block.

Information

This component checks the value of the dry bulb temperature. If the temperature is outside TMin and TMax, the simulation will stop with an error.

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.TemperatureTMin203.15Minimum allowed temperature
Modelica.Units.SI.TemperatureTMax343.15Maximum allowed temperature

Components

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInputTInInput Temperature
Modelica.Blocks.Interfaces.RealOutputTDryBulDry bulb temperature

Revisions

  • April 14, 2020, by Michael Wetter:
    Added noEvent.
    This is for #1340.
  • January 31, 2020 by Filip Jorissen:
    Improved error message.
  • October 27, 2011, by Wangda Zuo:
    Delete the unit conversion part and name it from ConvertTemperature to CheckTemperature.
  • March 23, 2011, by Michael Wetter:
    Set displayUnit argument for temperature output signal.
  • July 08, 2010, by Wangda Zuo:
    First implementation.