recordTSP_IIR_P1_395_T233_370
Extends from AixLib.DataBase.Media.Refrigerants.ThermodynamicStatePropertiesBaseDataDefinition.
Information
In this record, fitting coefficients are provided for thermodynamic properties calculated from two independent state variables. For detailed information of these thermodynamic properties as well as the fitting coefficients, please checkout AixLib.DataBase.Media.Refrigerants.ThermodynamicStatePropertiesBaseDataDefinition . The fitting coefficients are used in a hybrid refrigerant model provided in AixLib.Media.Refrigerants. For detailed information, please checkout AixLib.Media.Refrigerants.Interfaces.TemplateHybridTwoPhaseMediumRecord.
Assumptions and limitations
The provided coefficients are fitted to external data by Engelpracht
and are valid within the following range:
|
Parameter |
Minimum Value |
Maximum Value |
|
Pressure (p) in bar |
1 |
39.5 |
|
Temperature (T) in K |
233.15 |
370.15 |
The reference point is defined as 200 kJ/kg and 1 kJ/kg/K, respectively, for enthalpy and entropy for the saturated liquid at 273.15 K.
References
Engelpracht, Mirko (2017): Development of modular and scalable simulation models for heat pumps and chillers considering various refrigerants. Master Thesis
Revisions
- June 14, 2017, by Mirko Engelpracht, Christian Vering:
First implementation (see issue 408).