modelCellTemperatureMountingCloseToGround
Empirical model for determining the cell temperature of a PV module mounted with the
module backsite close to the ground
Extends from AixLib.Electrical.PVSystem.BaseClasses.PartialCellTemperature.
Information
Overview
Model for determining the cell temperature of a PV module mounted with the module backsite close to the ground, under operating conditions and under consideration of the wind velocity.
References
SANDIA REPORT SAND 2004-3535 Unlimited Release Printed December
2004 Photovoltaic Array Performance Model. (2005).
by King, D. L.
et al.