modelCellTemperatureMountingContactToGround
Empirical model for determining the cell temperature of a PV module mounted with the
module backsite in contact with the ground
Extends from AixLib.Electrical.PVSystem.BaseClasses.PartialCellTemperature.
Information
Overview
Model for determining the cell temperature of a PV module mounted with the module backside in contact with the ground, under operating conditions and under consideration of the wind velocity. E.g. roof integrated PV modules.
References
SANDIA REPORT SAND 2004-3535 Unlimited Release Printed December 2004 Photovoltaic Array Performance Model. (2005). by King, D. L. et al.