modelControllerOnOffModularCHP

Information

Model of an easy on-off-controller for the modular CHP model.

It allows to manually modulate the load of the power unit. A modulation factor (modFac) of 0 indicates that the machine is not in operation.

  • April, 2019  by Julian Matthes:
    First implementation (see issue #667)

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.TimestartTimeChp0Start time for discontinous simulation tests to heat the Chp unit up to the prescribed return temperature
Real[:,2]modTab[0.0, 0.8; 7200, 0.8; 7200, 0.93; 10800, 0.93; 10800, 0.62; 14400, 0.62; 14400, 0.8; 18000, 0.8; 18000, 0.0]Table for unit modulation (time = first column; modulation factors = second column)
Unit properties
AixLib.DataBase.CHP.ModularCHPEngineData.CHPEngDataBaseRecordCHPEngineModelDataBase.CHP.ModularCHPEngineData.CHP_ECPowerXRGI15()CHP engine data for calculations

Components

TypeNameDefaultDescription
Modelica.Blocks.Logical.TimertimerIsOff
Modelica.Blocks.Logical.Notnot1
Modelica.Blocks.Logical.LessThresholddeclarationTime
Modelica.Blocks.Logical.OrpumpControl
AixLib.Controls.Interfaces.CHPControlBusmodCHPConBus
Modelica.Blocks.Sources.TimeTablemodulationFactorControl
Modelica.Blocks.Logical.GreaterThresholdgreaterThreshold