recordNIBE_S2125_12

NIBE S2125 12

Extends from AixLib.Fluid.HeatPumps.ModularReversible.Data.TableData2D.GenericAirToWater.

Information

Data for air-to-water heat pump from NIBE. These tables are based on digitized data from manufacturer graphs. Temperature intervals are discretized with finer resolution in areas of high curvature to maintain accuracy. Electrical power PEle is calculated using the formula: PEle = Qmax / COP. Since manufacturers often provide COP and Qmax at different temperature points, PEle is calculated only at the temperature values common to both datasets to avoid extrapolation. As a result, the Qmax and PEle tables may differ in size.


NIBE S2125 Installateurhandbuch. Luft/Wasser-Wärmepumpe NIBE S2125.

Revisions

  • May 15, 2025 by Anton Lleshaj:
    First implementation (see issue #1593)