modelTableData2D

Extends from Modelica.Icons.Example, AixLib.Fluid.HeatPumps.ModularReversible.Validation.BaseClasses.PartialValidation.

Information

This validation case uses table-based data for the heat pump.

The approach was calibrated as a comparison to constant Carnot effectiveness approach in the conference paper for the heat pump model: https://doi.org/10.3384/ecp21181561

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.MassFlowRatemCon_flow_nominal0.404317Condenser nominal mass flow rate
Modelica.Units.SI.VolumeVCon0.004473Condenser volume
Modelica.Units.SI.FrequencyrefIneFreConst0.011848Cut off frequency for inertia of refrigerant cycle

Revisions

  • October 2, 2022 by Fabian Wuellhorst:
    First implementation (see issue #1576)