modelPoly_R407C_Unknown_Scroll
Scroll Compressor - R407C - Unknown displacement volume - Polynomial
Extends from PolynomialIsentropicEfficiency.
Information
This model contains a calculation procedure for the isentropic
efficiency presented by Karlsson (2007).
| Reference | Formula | Refrigerants |
Validity ncompressor
|
Validity Πpressure
|
|---|---|---|---|---|
| Karlsson2007 |
ηise = a1 + a2*π + a3*π^2 + a4*n +
a5*n^2
|
R407c |
No information
|
No information
|
References
F. Karlsson (2007): Capacity Control of Residential Heat Pump Heating Systems. In: PhD thesis
Revisions
- October 23, 2017, by Mirko Engelpracht:
First implementation (see issue 467).