modelSimpleHeatTransfer

Validation model to check the implementation of the simple heat transfer

Extends from Modelica.Icons.Example.

Information

This is a simple validation model to test the one-directional heat transfer. Therefore, an ambient temeprature is prediscribed and an expansion vassel is located at the model's outlet.

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.AbsolutePressurepInlMedium.pressure(Medium.setBubbleState(Medium.setSat_T(TInl + 2)))Current pressure at inlet conditions
Modelica.Units.SI.TemperatureTInl283.15Current temperature at inlet conditions
Modelica.Units.SI.AbsolutePressurepOutMedium.pressure(Medium.setDewState(Medium.setSat_T(TOut - 5)))Current set point of the compressor's outlet pressure
Modelica.Units.SI.TemperatureTOut333.15Current temperature at outlet conditions

Components

TypeNameDefaultDescription
Sources.MassFlowSource_TsourceSource of constant temperature and mass flow rate
Modelica.Thermal.HeatTransfer.Sources.FixedTemperaturefixTemFixed ambient temperature
Utilities.HeatTransfer.SimpleHeatTransfersimheaTraModel of simple one-dimensional heat transfer
MixingVolumes.MixingVolumesinkSink that allows storage of mass and energy

Contents

NameDescription
MediumMedium of the compressor

Revisions

  • October 30, 2017, by Mirko Engelpracht:
    First implementation (see issue 467).