modelPumpHeadControlled

testing the head controlled pump model.

Extends from Modelica.Icons.Example.

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.MassFlowRatem_flow_nominal0.1Nominal mass flow rate

Components

TypeNameDefaultDescription
.AixLib.Fluid.Movers.PumpsPolynomialBased.PumpHeadControlledpump
Modelica.Blocks.Sources.RamprampValvePosition
AixLib.Fluid.Sources.Boundary_pTvessle
Modelica.Blocks.Sources.BooleanPulsePumpOn1
Modelica.Blocks.Sources.RamprampPumpDp
BaseClasses.PumpBuspumpBus
Actuators.Valves.TwoWayLinearsimpleValve

Contents

NameDescription
Medium

Revisions

  • 2019-09-18 by Alexander Kuempel:
    Renaming and restructuring.
  • 2018-03-01 by Peter Matthes:
    Adjusted parameter settings. From pump model removed Nstart (became Nnom in pump model) and m_flow_start (should be used as output from pump rather than a setting). Changed setting of system.m_flow_start to become pump.m_flow_start.
  • 2018-02-01 by Peter Matthes
    Switches pump off near end of simulation to check for handling of power and efficiency calculation. Improves plot script.
  • 2018-01-29 by Peter Matthes:
    * Removes parameter useABCformula in pump model and changes pump record to Stratos_Pico_25_1_6.
    * The selectable function for efficiency calculation could be removed from the parameter dialog.
  • 2018-01-26 by Peter Matthes:
    Changes parameter name n_start into Nstart in the pump models.
  • 2017-11-22 by Peter Matthes
    Implemented