modelPumpHeadControlled
testing the head controlled pump model.
Extends from Modelica.Icons.Example.
Parameters
| Type | Name | Default | Description |
| Modelica.Units.SI.MassFlowRate | m_flow_nominal | 0.1 | Nominal mass flow rate |
Components
| Type | Name | Default | Description |
| .AixLib.Fluid.Movers.PumpsPolynomialBased.PumpHeadControlled | pump | | |
| Modelica.Blocks.Sources.Ramp | rampValvePosition | | |
| AixLib.Fluid.Sources.Boundary_pT | vessle | | |
| Modelica.Blocks.Sources.BooleanPulse | PumpOn1 | | |
| Modelica.Blocks.Sources.Ramp | rampPumpDp | | |
| BaseClasses.PumpBus | pumpBus | | |
| Actuators.Valves.TwoWayLinear | simpleValve | | |
Revisions
- 2019-09-18 by Alexander Kuempel:
Renaming and restructuring.
- 2018-03-01 by Peter Matthes:
Adjusted parameter settings. From pump model removed Nstart (became
Nnom in pump model) and m_flow_start (should be used as output from
pump rather than a setting). Changed setting of system.m_flow_start
to become pump.m_flow_start.
- 2018-02-01 by Peter Matthes
Switches pump off near end of simulation to check for handling of
power and efficiency calculation. Improves plot script.
- 2018-01-29 by Peter Matthes:
* Removes parameter useABCformula in pump model and changes pump
record to Stratos_Pico_25_1_6.
* The selectable function for efficiency calculation could be
removed from the parameter dialog.
- 2018-01-26 by Peter Matthes:
Changes parameter name n_start into Nstart in the pump models.
- 2017-11-22 by Peter Matthes
Implemented