modelPump
Ideal pump
Extends from AixLib.Obsolete.BaseClasses.ObsoleteModel.
Information
Overview
Model for an ideal pump.
Assumptions
Ideal pump
Concept
The input and output of the pump include respectively following values:
- mass flow rate
- temperature
- specific enthalpy
- specific heat capacity
The pump uses the real input to set the mass flow rate. The specific heat capacity of the medium can be set as a parameter, default value is referred to the record SimpleMedium. The temperature and the specific enthalpy remain constant.
Example Results
Examples can be found in Pump
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| FastHVAC.Media.BaseClasses.MediumSimple | medium | FastHVAC.Media.WaterSimple() | Standard charastics for water (heat capacity, density, thermal conductivity) |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Blocks.Interfaces.RealInput | dotm_setValue | External real input to set the mass flow rate | |
| FastHVAC.Interfaces.EnthalpyPort_a | enthalpyPort_a | Thermal port for input values (temperature, mass flow rate, specific enthalpy, constant specific heat capacity) | |
| FastHVAC.Interfaces.EnthalpyPort_b | enthalpyPort_b | Thermal port for output values (temperature, mass flow rate, specific enthalpy, constant specific heat capacity) |
Revisions
-
December 16, 2014 by Konstantin Finkbeiner:
Implemented