modelHeatConvPipeInside

Model for Heat Transfer through convection inside a pipe, based on Nussel Correlations

Extends from AixLib.Obsolete.BaseClasses.ObsoleteModel, Modelica.Thermal.HeatTransfer.Interfaces.Element1D.

Information

Overview

This model represents the phenomenon of heat convection inside a pipe by a flowing medium.

The heat transfer coefficient at the inside could be calculated by formular from VDI-Waermeatlas or a fixed value can be choosen.

  • August 11, 2017; by David Jansen:

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.Lengthlengthlength of total pipe
Modelica.Units.SI.Lengthd_iinner diameter of pipe
Modelica.Units.SI.Lengthd_aouter diameter of pipe
Modelica.Units.SI.AreaA_sursurface for heat transfer
BooleancalcHContrueUse calculated value for inside heat coefficient
Modelica.Units.SI.CoefficientOfHeatTransferhConIn_const30Constant convective heat transfer coefficient (Inside)
Obsolete.YearIndependent.FastHVAC.Media.BaseClasses.MediumSimplemediumObsolete.YearIndependent.FastHVAC.Media.WaterSimple()

Components

TypeNameDefaultDescription
Modelica.Units.SI.ReynoldsNumberRe
Modelica.Units.SI.Velocityv
Modelica.Units.SI.NusseltNumberNu
Modelica.Units.SI.NusseltNumberNu_lam_1
Modelica.Units.SI.NusseltNumberNu_lam_2
Modelica.Units.SI.NusseltNumberNu_lam
Modelica.Units.SI.NusseltNumberNu_tur
Modelica.Units.SI.PrandtlNumberPr
Modelica.Units.SI.CoefficientOfHeatTransferhConConvective heat transfer coefficient
Realzetapressure loss coefficient
Modelica.Blocks.Interfaces.RealInputm_flow