modelGroundFloorBuildingEnvelope
Extends from AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoomParams.
Information
Overview
Model for the envelope of the ground floor.
Ground temperature
The ground temperature can be coupled to any desired prescriped temperature. Anyway, suitable ground temperatures depending on locations in Germany are listed as Θ'_m,e in the comprehensive table 1 in "Beiblatt 1" in the norm DIN EN 12831.
Or a ground temperature can be chosen according to a TRY region, which is listed below: if ...
TRY_Region == 1 then 282.15 K
TRY_Region == 2 then 281.55 K
TRY_Region == 3 then 281.65 K
TRY_Region == 4 then 282.65 K
TRY_Region == 5 then 281.25 K
TRY_Region == 6 then 279.95 K
TRY_Region == 7 then 281.95 K
TRY_Region == 8 then 279.95 K
TRY_Region == 9 then 281.05 K
TRY_Region == 10 then 276.15 K
TRY_Region == 11 then 279.45 K
TRY_Region == 12 then 283.35 K
TRY_Region == 13 then 281.05 K
TRY_Region == 14 then 281.05 K
TRY_Region == 15 then 279.95 K
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Dynamics › Equations | |||
| Modelica.Fluid.Types.Dynamics | energyDynamics | Modelica.Fluid.Types.Dynamics.DynamicFreeInitial | Type of energy balance: dynamic (3 initialization options) or steady state |
| Dimensions | |||
| Modelica.Units.SI.Length | room_width | 3.92 | width |
| Modelica.Units.SI.Height | room_height | 2.60 | height |
| Modelica.Units.SI.Length | length1 | 3.3 | l1 |
| Modelica.Units.SI.Length | length2 | 2.44 | l2 |
| Modelica.Units.SI.Length | length3 | 1.33 | l3 |
| Modelica.Units.SI.Length | length4 | 3.3 | l4 |
| Modelica.Units.SI.Length | thickness_IWsimple | 0.145 | thickness IWsimple |
| Windows and Doors | |||
| Modelica.Units.SI.Area | windowarea_11 | 8.44 | Area Window11 |
| Modelica.Units.SI.Area | windowarea_12 | 1.73 | Area Window12 |
| Modelica.Units.SI.Area | windowarea_22 | 1.73 | Area Window22 |
| Modelica.Units.SI.Area | windowarea_41 | 1.4 | Area Window41 |
| Modelica.Units.SI.Area | windowarea_51 | 3.46 | Area Window51 |
| Modelica.Units.SI.Area | windowarea_52 | 1.73 | Area Window52 |
| Modelica.Units.SI.Length | door_width_31 | 1.01 | Width Door31 |
| Modelica.Units.SI.Length | door_height_31 | 2.25 | Height Door31 |
| Modelica.Units.SI.Length | door_width_42 | 1.25 | Width Door42 |
| Modelica.Units.SI.Length | door_height_42 | 2.25 | Height Door42 |
| Outer walls › Doors | |||
| Modelica.Units.SI.CoefficientOfHeatTransfer | UValOutDoors | U-value (thermal transmittance) of doors in outer walls | |
| Modelica.Units.SI.Emissivity | epsOutDoors | 0.95 | Emissivity of inside surface of outer doors |
| Dynamic ventilation | |||
| Modelica.Units.SI.Temperature | Tset_Livingroom | 295.15 | Tset_livingroom |
| Modelica.Units.SI.Temperature | Tset_Hobby | 295.15 | Tset_hobby |
| Modelica.Units.SI.Temperature | Tset_Corridor | 291.15 | Tset_corridor |
| Modelica.Units.SI.Temperature | Tset_WC | 291.15 | Tset_WC |
| Modelica.Units.SI.Temperature | Tset_Kitchen | 295.15 | Tset_kitchen |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Rooms.OFD.Ow2IwL2IwS1Gr1Uf1 | Livingroom | ||
| Rooms.OFD.Ow2IwL1IwS1Gr1Uf1 | Hobby | ||
| Rooms.OFD.Ow2IwL1IwS1Gr1Uf1 | WC_Storage | ||
| Rooms.OFD.Ow2IwL2IwS1Gr1Uf1 | Kitchen | ||
| Rooms.OFD.Ow1IwL2IwS1Gr1Uf1 | Corridor | ||
| Utilities.Interfaces.SolarRad_in | North | ||
| Utilities.Interfaces.SolarRad_in | East | ||
| Utilities.Interfaces.SolarRad_in | South | ||
| Utilities.Interfaces.SolarRad_in | West | ||
| Modelica.Blocks.Interfaces.RealInput | WindSpeedPort | ||
| Modelica.Blocks.Interfaces.RealInput[5] | AirExchangePort | 1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor, 4: WC_Storage_GF, 5: Kitchen_GF | |
| Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a | thermCeiling_Livingroom | ||
| Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a | thermCeiling_Hobby | ||
| Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a | thermCeiling_Corridor | ||
| Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a | thermCeiling_WCStorage | ||
| Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a | thermCeiling_Kitchen | ||
| Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a | thermCorridor | ||
| Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a[5] | groundTemp | HeatPort to force a ground temperature for the ground level's floor. | |
| Utilities.Interfaces.Adaptors.ConvRadToCombPort[5] | heatStarToCombHeaters | ||
| Utilities.Interfaces.ConvRadComb[5] | portConvRadRooms | 1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor, 4: WC_Storage_GF, 5: Kitchen_GF | |
| Modelica.Fluid.Interfaces.FluidPort_a[5] | portVent_in | Inlet for ventilation | |
| Modelica.Fluid.Interfaces.FluidPort_b[5] | portVent_out | Outlet of Ventilation | |
| Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a | thermOutside |
Contents
| Name | Description |
|---|---|
| Medium |
Revisions
-
April 23, 2020 by Philipp Mehrfeld:
#752: Propagate all parameters correctly (not geometry). Vectorize thermal ports. Delete TIR and TMC. -
April 18, 2014 by Ana Constantin:
Added documentation -
July 10, 2011 by Ana Constantin:
Implemented