modelCase650

Extends from AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.BaseClasses.PartialCase.

Information

Input Specifications of Case 650 as described in ASHRAE Standard 140:

Difference to case 600:

  • Air exchange rate: 10.8
  • 18-7 h: Vent fan = ON
  • 7-18 h: Vent fan = OFF
  • Heating = always OFF
  • 18-7 h: Cool = OFF
  • 7-18 h: Cool =ON IF Temp < 27°C, otherwise Cool=OFF

Parameters

TypeNameDefaultDescription
AixLib.DataBase.Profiles.ProfileBaseDataDefinitionSetTempProfileAixLib.DataBase.Profiles.ASHRAE140.SetTemp_caseX50()
AixLib.DataBase.Profiles.ProfileBaseDataDefinitionAERProfileAixLib.DataBase.Profiles.ASHRAE140.Ventilation_caseX50()

Components

TypeNameDefaultDescription
Utilities.Sources.HeaterCooler.HeaterCoolerPIidealHeaterCooler
Modelica.Blocks.Sources.RealExpressionHeatingPower
Modelica.Blocks.Sources.CombiTimeTableAirExchangeRate
Modelica.Blocks.Sources.CombiTimeTableSource_TsetCool