modelCase650
Extends from AixLib.ThermalZones.HighOrder.Validation.ASHRAE140.BaseClasses.PartialCase.
Information
Input Specifications of Case 650 as described in ASHRAE Standard 140:
Difference to case 600:
- Air exchange rate: 10.8
- 18-7 h: Vent fan = ON
- 7-18 h: Vent fan = OFF
- Heating = always OFF
- 18-7 h: Cool = OFF
- 7-18 h: Cool =ON IF Temp < 27°C, otherwise Cool=OFF
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| AixLib.DataBase.Profiles.ProfileBaseDataDefinition | SetTempProfile | AixLib.DataBase.Profiles.ASHRAE140.SetTemp_caseX50() | |
| AixLib.DataBase.Profiles.ProfileBaseDataDefinition | AERProfile | AixLib.DataBase.Profiles.ASHRAE140.Ventilation_caseX50() |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Utilities.Sources.HeaterCooler.HeaterCoolerPI | idealHeaterCooler | ||
| Modelica.Blocks.Sources.RealExpression | HeatingPower | ||
| Modelica.Blocks.Sources.CombiTimeTable | AirExchangeRate | ||
| Modelica.Blocks.Sources.CombiTimeTable | Source_TsetCool |