modelComparisonThermalZoneMoistAndDryAir
Illustrates the difference between ThermalZone and ThermalZoneMoistAir
Extends from Modelica.Icons.Example.
Information
This example illustrates the difference between AixLib.ThermalZones.ReducedOrder.ThermalZone.ThermalZone AixLib.ThermalZones.ReducedOrder.ThermalZone.ThermalZoneMoistAir. Parameter set for thermal zone is for an office zone of an office building build as passive house. All boundary conditions are generic to show how to apply different kinds of boundary conditions. The results should show a typical profile for indoor air temperatures, but are not related to a specific building or measurement data.
Components
| Type | Name | Default | Description |
|---|---|---|---|
| AixLib.ThermalZones.ReducedOrder.ThermalZone.ThermalZone | thermalZoneMoistAir | Thermal zone | |
| AixLib.BoundaryConditions.WeatherData.ReaderTMY3 | weaDat | Weather data reader | |
| Modelica.Blocks.Sources.CombiTimeTable | internalGains | Table with profiles for internal gains | |
| Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow | prescribedHeatFlow | Radiative heat flow of additional internal gains | |
| Modelica.Blocks.Sources.Sine | sine | Sinusoidal excitation for additional internal gains | |
| Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow | prescribedHeatFlow1 | Convective heat flow of additional internal gains | |
| Modelica.Blocks.Math.Gain | gain | Split additional internal gains into radiative an convective | |
| Modelica.Blocks.Math.Gain | gain1 | Split additional internal gains into radiative an convective | |
| AixLib.Fluid.Sources.MassFlowSource_T | sourcAir | mass flow rate of air into thermal zone | |
| AixLib.Fluid.Sources.Boundary_pT | sinAir | sink of air | |
| AixLib.ThermalZones.ReducedOrder.ThermalZone.ThermalZone | thermalZone | Thermal zone | |
| Modelica.Blocks.Sources.CombiTimeTable | internalGains1 | Table with profiles for internal gains | |
| Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow | prescribedHeatFlow2 | Radiative heat flow of additional internal gains | |
| Modelica.Blocks.Sources.Sine | sine1 | Sinusoidal excitation for additional internal gains | |
| Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow | prescribedHeatFlow3 | Convective heat flow of additional internal gains | |
| Modelica.Blocks.Math.Gain | gain2 | Split additional internal gains into radiative an convective | |
| Modelica.Blocks.Math.Gain | gain3 | Split additional internal gains into radiative an convective | |
| AixLib.Fluid.Sources.MassFlowSource_T | sourcAir1 | mass flow rate of air into thermal zone | |
| AixLib.Fluid.Sources.Boundary_pT | sinAir1 | sink of air |
Revisions
- April, 2019, by Martin Kremer:
First Implementation.