modelShutterControl
Information
Control model of shutters opening and closing
Hypothesis and equations
Control model of shutters opening:
- closure during night (between closing time and opening time)
- occultation during summer with a hysteresis depending on the indoor temperature when the housing is occupied
Bibliography
none
Instructions for use
none
Known limits / Use precautions
none
Validations
Non-validated model - Vincent Magnaudeix 06/2013
--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Vincent MAGNAUDEIX, EDF (2013)
--------------------------------------------------------------
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Night closure | |||
| Integer | HeureOuvertureMatin | 8 | Shutters opening time in the morning |
| Integer | HeureFermetureSoir | 21 | Shutters closing time in the evening |
| Summer comfort | |||
| Modelica.Units.SI.Temperature | Tfermeture | 299.15 | Indoor temperature beyond which shutters are closed during the day |
| Modelica.Units.SI.Temperature | Touverture | 297.15 | Indoor temperature below which shutters are opened during the day |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Blocks.Interfaces.RealInput | Tint | Indoor temperature in K | |
| Modelica.Blocks.Interfaces.RealInput | Occupation | 1 - occupancy ; 0 - absence | |
| Modelica.Blocks.Interfaces.RealOutput | TauxFermeture | shutters occultancy level | |
| Modelica.Blocks.Interfaces.RealInput | OnOff_CommandeVolet | 1- shutters control is possible 0- no shutters control |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Real | TauxOccultation | Shutters occultancy level during the day | |
| Integer | Hyst1 | Temperature hysteresis | |
| Modelica.Blocks.Sources.Pulse | pulse | ||
| Modelica.Blocks.Math.MultiProduct | product | ||
| Modelica.Blocks.Sources.RealExpression | Taux_occultation | ||
| Modelica.Blocks.Math.Max | max | ||
| Modelica.Blocks.Sources.RealExpression | hysteresis_temperature | ||
| Modelica.Blocks.Math.MultiProduct | product1 |
Revisions
Amy Lindsay 03/2014 : suppression des Real to Boolean et Boolean to Real qui consomment énormément de temps de calcul
Amy Lindsay 04/2014 : sortie Taux de fermeture des volets (et non taux d'ouverture !) pour cohérence avec modèles de vitrage