modelUnheatedRoom

Unheated room to be used as landing for complete collective housing assembly
Diagram of UnheatedRoom

Information

Unheated room

Hypothesis and equations

Pure thermal modelled unheated room.

To be complete, the model should be connected to the different apartment models, which contain common wall models.

Height under ceiling : 2.5m.

Bibliography

Site of building stock library

Notes H-E10-1996-02908-FR and H-E13-2014-00591-FR

Instructions for use

Wall and glazing surfaces come from SettingsUnheatedRoom record.

To change a surface value, prefer to modify it in the record rather than in the assembly.

Parameters depending on RT (French building regulation) are stored in BuildingDataUNHEATEDROOM records.

When one of these records is selectied thanks to paraMaisonRT, building envelope parameters (walls, windows, ventilation...) will take the values stored in the selected record.

Available parameters are listed below :

  • paraMaisonRT : choice of the RT (French building regulation))
  • PositionEtage : 1 if ground floor, 2 if intermediat floore, 3 if last floor. it is possible to assembly a n floor building with a numbering such as : 1 - 2 - .... - 2 - 3

Known limits / Use precautions

none

Validations

Validated model - Frédéric Gastiger 01/2014

See note H-E13-2014-00591-FR for validation

--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Frédéric GASTIGER, EDF (2014)
--------------------------------------------------------------

Parameters

TypeNameDefaultDescription
Overall parameters
BuildSysPro.BuildingStock.Utilities.Records.BuildingData.CollectiveHousing.BuildingDataUNHEATEDROOM.BuildingTypeparaMaisonRTFrench building regulation to use
IntegerPositionEtage2Floor position
Realbeta0Correction of azimuth for vertical walls such as azimuth=beta+azimuth, {beta=0 : N=180,S=0,E=-90,O=90}
Advanced parameters
BooleanGLOEXTfalseIntegration of LW radiation (infrared) toward the environment and the sky
BuildSysPro.Utilities.Types.InitCondInitTypeBuildSysPro.Utilities.Types.InitCond.SteadyStateType of initialization for walls
Modelica.Units.SI.TemperatureTp293.15Initial temperature of walls

Connectors

TypeNameDefaultDescription
BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_aT_extExterior temperature
BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_aT_int_landingStairwell temperature
BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_bT_int_infLower unheated room temperature
BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_aT_sky
Modelica.Blocks.Interfaces.RealInput[10]GDIFH, DIRN, DIRH, GLOH, t0, CosDir[1:3], solar azimuth angle, solar elevation angle