modelMozartMultizone
Information
Mozart Multizone individual housing
Hypothesis and equations
none
Bibliography
none
Instructions for use
Parameter paraMaisonRT allows the user to chose a specific French building regulation for the building, so that building envelope parameters (walls, windows, ventilation...) will be automatically filled with data from the choosen record.
Detail of thermal bridge vectors :
- TauPonts[1] and ValeursK[1] : exterior wall / exterior wall
- TauPonts[2] and ValeursK[2] : exterior wall / supporting wall
- TauPonts[3] and ValeursK[3] : exterior wall / floor
- TauPonts[4] and ValeursK[4] : floor / crawlspace
- TauPonts[5] and ValeursK[5] : supporting wall / floor
- TauPonts[6] and ValeursK[6] : exterior wall / attic wall
- TauPonts[7] and ValeursK[7] : attic wall / attic
- TauPonts[8] and ValeursK[8] : door
- TauPonts[9] and ValeursK[9] : windows
Known limits / Use precautions
For dates of contruction from 1974 to 1989, insulating materials thicknesses in floors are different between building stock site and Clim 2000 (cf Records.WallData.IndividualHousing documentation).
Validations
Validated model by comparison of GV with Clim 2000 - Alexandre Hautefeuille, Gilles Plessis, Amy Lindsay 04/2014
--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Alexandre HAUTEFEUILLE, Gilles PLESSIS, Amy LINDSAY, EDF (2014)
--------------------------------------------------------------
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | beta | 0 | Correction of azimuth for vertical walls such as azimuth=beta+azimuth, {beta=0 : N=180,S=0,E=-90,O=90} |
| Choice of RT | |||
| BuildSysPro.BuildingStock.Utilities.Records.BuildingData.IndividualHousing.BuildingDataMOZART.BuildingType | paraMaisonRT | French building regulation to use | |
| Thermal flows | |||
| Boolean | GLOEXT | false | Integration of LW radiation (infrared) toward the environment and the sky |
| Boolean | CLOintPlancher | true | Floor : solar fluxes are absorbed only by the floor; All walls : solar fluxes are absorbed by all the walls and partition walls in proportion of surfaces |
| Boolean | QVin | false | Input : controlled air change rate; Constant : constant air change rate |
| Walls | |||
| Modelica.Units.SI.Temperature | Tp | 293.15 | Initial temperature of walls |
| BuildSysPro.Utilities.Types.InitCond | InitType | BuildSysPro.Utilities.Types.InitCond.SteadyState | Type of initialization for walls |
| Windows | |||
| Boolean | useVolet | false | Use of window shutters |
| Boolean | useOuverture | false | Control of windows opening |
| Boolean | useReduction | false | Implementation of solar reduction factors (masking, frame) |
| Windows › Parameters | |||
| Integer | TypeFenetrePF | 1 | Choice of type of window |
| Real | voilage | 0.95 | Presence of net curtains : = 0.95 if yes and = 1 if not |
| Real | position | 0.90 | Glazing position: = 0.9 if inner and = 1 if outer |
| Real | rideaux | 0.85 | Presence of curtains: = 0.85 if yes and = 1 if not |
| Real | ombrages | 0.85 | Obstacles shading (vegetation, neighborhood): = 0.85 if yes et = 1 if not |
| Windows › Reduction factor if useReduction = false | |||
| Real | r1 | paraMaisonRT.transmissionMenuiserieFenetres | Reduction factor for direct radiation if useReduction = false |
| Real | r2 | paraMaisonRT.transmissionMenuiserieFenetres | Reduction factor for diffuse radiation if useReduction = false |
| French windows | |||
| Boolean | useVoletPF | false | Use of window shutters |
| Boolean | useOuverturePF | false | Control of windows opening |
| Boolean | useReduction1 | false | Implementation of solar reduction factors (masking, frame) |
| French windows › Parameters | |||
| Integer | TypeFenetrePF1 | 1 | Choice of type of French window |
| Real | voilage1 | 0.95 | Presence of net curtains : = 0.95 if yes and = 1 if not |
| Real | position1 | 0.90 | Glazing position: = 0.9 if inner and = 1 if outer |
| Real | rideaux1 | 0.85 | Presence of curtains: = 0.85 if yes and = 1 if not |
| Real | ombrages1 | 0.85 | Obstacles shading (vegetation, neighborhood): = 0.85 if yes et = 1 if not |
| French windows › Reduction factor if useReduction = false | |||
| Real | r11 | paraMaisonRT.transmissionMenuiseriePortesFenetres | Reduction factor for direct radiation if useReduction = false |
| Real | r21 | paraMaisonRT.transmissionMenuiseriePortesFenetres | Reduction factor for diffuse radiation if useReduction = false |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_a | T_sky | ||
| Modelica.Blocks.Interfaces.RealInput[10] | G | DIFH, DIRN, DIRH, GLOH, t0, CosDir[1:3], Solar azimuth angle , Solar elevation angle | |
| BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_a | T_ext | ||
| Modelica.Blocks.Interfaces.RealInput[2] | V | Wind speed (m/s) and direction (from 0° - North, 90° - East, 180° - South, 270 ° - West) | |
| Modelica.Blocks.Interfaces.RealInput | RenouvAir | [m3/h] | |
| BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_a | T_int_living | ||
| BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_a | T_int_kitchen | ||
| BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_a | T_int_room1 | ||
| BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_a | T_int_room2 | ||
| BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_a | T_int_room3 | ||
| BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_a | T_int_bathroom | ||
| BuildSysPro.BaseClasses.HeatTransfer.Interfaces.HeatPort_a | T_int_entrance | ||
| Modelica.Blocks.Interfaces.BooleanInput[2] | ouvertureSejour | Opening of south, west windows (true = open, false = closed) | |
| Modelica.Blocks.Interfaces.BooleanInput[1] | ouvertureCuisine | Opening of north windows (true = open, false = closed) | |
| Modelica.Blocks.Interfaces.BooleanInput[1] | ouvertureChambre1 | Opening of north windows (true = open, false = closed) | |
| Modelica.Blocks.Interfaces.BooleanInput[1] | ouvertureChambre2 | Opening of east windows (true = open, false = closed) | |
| Modelica.Blocks.Interfaces.BooleanInput[2] | ouvertureChambre3 | Opening of south, east windows (true = open, false = closed) | |
| Modelica.Blocks.Interfaces.RealInput[2] | fermetureSejour | Closing of south, west shutters (0 - open, 1 - closed) | |
| Modelica.Blocks.Interfaces.RealInput[1] | fermetureCuisine | Closing of north shutters (0 - open, 1 - closed) | |
| Modelica.Blocks.Interfaces.RealInput[1] | fermetureChambre1 | Closing of north shutters (0 - open, 1 - closed) | |
| Modelica.Blocks.Interfaces.RealInput[1] | fermetureChambre2 | Closing of east shutters (0 - open, 1 - closed) | |
| Modelica.Blocks.Interfaces.RealInput[2] | fermetureChambre3 | Closing of south, east shutters (0 - open, 1 - closed) | |
| Modelica.Blocks.Interfaces.RealInput[1] | fermetureSDB | Closing of south shutters (0 - open, 1 - closed) |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| BuildSysPro.BoundaryConditions.Weather.ZoneWind | vENTzone |
Revisions
Stéphanie Froidurot - 10/2020 : Add internal doors