recordBuildingType

List of Matisse collective housing construction dates

Information

Record of Matisse collective housing settings according to the date of construction

Hypothesis and equations

none

Bibliography

Site of the building stock library

Note H-E10-1996-02908-FR

Instructions for use

Detail of thermal bridge vectors :

  • TauPonts[1] and ValeursK[1] : exterior wall / common wall
  • TauPonts[2] and ValeursK[2] : unheated room wall / common wall
  • TauPonts[3] and ValeursK[3] : exterior wall / intermediate floor
  • TauPonts[4] and ValeursK[4] : exterior wall / intermediate ceiling
  • TauPonts[5] and ValeursK[5] : unheated room wall / intermediate floor
  • TauPonts[6] and ValeursK[6] : unheated room wall / intermediate ceiling
  • TauPonts[7] and ValeursK[7] : door
  • TauPonts[8] and ValeursK[8] : windows
  • TauPontsPlancher[1] and ValeursKPlancher[1] : intermediate floor / exterior wall of basement
  • TauPontsPlancher[2] and ValeursKPlancher[2] : intermediate floor / unheated room wall of basement
  • TauPontsPlancher[3] and ValeursKPlancher[3] : intermediate floor / common wall of basement
  • TauPontsPlafond[1] and ValeursKPlafond[1] : intermediate ceiling / exterior wall of ceiling
  • TauPontsPlafond[2] and ValeursKPlafond[2] : intermediate ceiling / unheated room wall of ceiling
  • TauPontsPlafond[3] and ValeursKPlafond[3] : intermediate ceiling / common wall of ceiling

Known limits / Use precautions

none

Validations

Validated model - Alexandre Hautefeuille, Gilles Plessis, Amy Lindsay 04/2014

--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Alexandre HAUTEFEUILLE, Gilles PLESSIS, Amy LINDSAY, EDF (2014)
--------------------------------------------------------------

Parameters

TypeNameDefaultDescription
BuildSysPro.Utilities.Types.InitCondInitTypeBuildSysPro.Utilities.Types.InitCond.SteadyState
Walls › Interior walls
BuildSysPro.Utilities.Records.GenericWallPlancherMitoyenCommon floor
BuildSysPro.Utilities.Records.GenericWallPlafondMitoyenCommon ceiling
BuildSysPro.Utilities.Records.GenericWallPorteDoor
BuildSysPro.Utilities.Records.GenericWallPorteIntInterior door
BuildSysPro.Utilities.Records.GenericWallMurMitoyenCommon wall
BuildSysPro.Utilities.Records.GenericWallMurPalierLanding wall
BuildSysPro.Utilities.Records.GenericWallCloisonsPartition wall
Walls › Exterior walls
BuildSysPro.Utilities.Records.GenericWallMurExtExterior wall
BuildSysPro.Utilities.Records.GenericWallPlafondImmeubleBuilding ceiling
BuildSysPro.Utilities.Records.GenericWallPlancherImmeubleBuilding floor
RealalphaExt0.3Absorption coefficient of exterior walls in the visible spectrum
Realeps0Emissivity of exterior walls for long wavelength radiation
Thermal flows › Surface exchange coefficients (Warning : take care to consider or not long wavelength radiation exchanges according to GLOEXT parameter)
Modelica.Units.SI.CoefficientOfHeatTransferhsExtVert25Surface exchange coefficient on the outer face of vertical walls
Modelica.Units.SI.CoefficientOfHeatTransferhsIntVert7.69Surface exchange coefficient on the inner face of vertical walls
Modelica.Units.SI.CoefficientOfHeatTransferhsExtHor25Surface exchange coefficient on the outer face of horizontal walls
Modelica.Units.SI.CoefficientOfHeatTransferhsIntHorHaut10Surface exchange coefficient on the inner face of horizontal walls when the thermal flow is upwards
Modelica.Units.SI.CoefficientOfHeatTransferhsIntHorBas5.88Surface exchange coefficient on the inner face of horizontal walls when the thermal flow is downwards
Windows
Modelica.Units.SI.CoefficientOfHeatTransferUvitrageAFCoefficient of heat transfert of the window with closing (conduction+convection)
Modelica.Units.SI.CoefficientOfHeatTransferUvitrageSFCoefficient of heat transfert of the window without closing (conduction+convection)
RealtransmissionMenuiserieFenetres(1 - 0.3)*0.9Light transmission due to window frame
Realeps_vitrage0Emissivity in long wavelength radiation
Thermal flows › Air renewal
RealrenouvAirAir renewal rate in vol/h
Thermal bridges
Real[8]ValeursKK coefficient for each linear heat loss relating to a thermal bridge in [W/(m.K)]
Real[8]TauPontsTau reduction coefficient of each thermal bridge
Real[3]ValeursKPlafondK coefficient for each linear heat loss relating to a thermal bridge on ceiling in [W/(m.K)]
Real[3]TauPontsPlafondTau reduction coefficient of each thermal bridge on ceiling
Real[3]ValeursKPlancherK coefficient for each linear heat loss relating to a thermal bridge on floor in [W/(m.K)]
Real[3]TauPontsPlancherTau reduction coefficient of each thermal bridge on floor
RealPontsTh_GeneriqueValue of thermal bridge common to all possible positions of the apartment (used in complete collective housing building assembly)
RealPontsTh_BasValue of thermal bridge specific to an apartment on first floor (used in complete collective housing building assembly)
RealPontsTh_HautValue of thermal bridge specific to an apartment on last floor (used in complete collective housing building assembly)
Boundary conditions in temperature
RealbLNC0.1Weighting coefficient of boundary conditions in temperature for unheated rooms
RealbPlancherWeighting coefficient of boundary conditions in temperature for floor
RealbPlafondWeighting coefficient of boundary conditions in temperature for ceiling

Revisions

Benoît Charrier 05/2015 : ajout de paramètres nécessaires au modèle MatisseAssemblageLC