modelMultipleFloorsVectors

Test case for air flow between multiple floors in vector design

Extends from Modelica.Icons.Example (Icon for runnable examples).

Information

A fully scalable air flow benchmark model

Typical use and important parameters

With nZones and nFloors, this vectorized model can be scaled to represent a simple building of any size.

References

Inspired by IBPSA.Airflow.Multizone.Validation.ThreeRoomsContam

Parameters

TypeNameDefaultDescription
IntegernZones4Number of zone elements per floor
IntegernFloors2Number of floors
Modelica.Units.SI.TemperatureTRoom298.15Indoor air temperature of room in K
Modelica.Units.SI.TemperatureTHallway293.15Indoor air temperature of hallway in K
Modelica.Units.SI.TemperatureTStaircase293.15Indoor air temperature of staircase in K
Modelica.Units.SI.HeightheightRooms3Height of rooms in m
Modelica.Units.SI.LengthlengthZone5Length of room in m
Modelica.Units.SI.LengthwidthZone5Width of room in m
Modelica.Units.SI.LengthwidthHallway3Width of room in m
RealdoorOpening1Opening of door (between 0:closed and 1:open)
BooleanforceErrorControlOnFlowtrueFlag to force error control on m_flow. Set to true if interested in flow rate

Components

TypeNameDefaultDescription
Components.Floor[nFloors]floorVector of floor elements
BoundaryConditions.WeatherData.ReaderTMY3weaDatWeather data reader for input into floor models

Contents

NameDescription
Medium

Revisions

  • February 2015 by Marcus Fuchs:
    First implementation