modelCase900FF

Test with heavy-weight construction and free floating temperature
Diagram of Case900FF

Extends from IBPSA.ThermalZones.ISO13790.Validation.BESTEST.Case600FF (Basic test with light-weight construction and free floating temperature).

Information

This model is used for the test case 900FF of the BESTEST validation suite. Case 900FF is a heavy-weight building. The room temperature is free floating.

Components

TypeNameDefaultDescription
Zone5R1C.Zonezon5R1C (from Case600FF)Thermal zone
IBPSA.BoundaryConditions.WeatherData.ReaderTMY3weaDat (from Case600FF)Weather data
Modelica.Blocks.Sources.ConstantintGai (from Case600FF)Internal heat gains
Modelica.Blocks.Math.ContinuousMeanconMea (from Case600FF)Continuous mean of room air temperature
Modelica.Blocks.Sources.CombiTimeTabledaiComBESTESTFF (from Case600FF)Daily comparison BESTEST FF
IBPSA.ThermalZones.ISO13790.Validation.BESTEST.Data.Case600FFResultsannComBESTESTFF (from Case600FF)Annual comparison BESTEST FF

Revisions

  • Mar 16, 2022, by Alessandro Maccarini:
    First implementation.