modelParallelTubesActiveSolarWall
a tube height in the solar active wall
Information
Hypothesis and equations
none
Bibliography
none
Instructions for use
none
Known limits / Use precautions
none
Validations
none
--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Emmanuel AMY DE LA BRETEQUE, EDF (2010)
--------------------------------------------------------------
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.NonSI.Temperature_degC | Tstart | 25 | |
| Integer | n | 10 | number of meshes according to the direction of the tube |
| Modelica.Units.SI.Area | Stot | 9 | solar collection surface |
| Modelica.Units.SI.MassFlowRate | q | Stot*30/3600 | total mass flow |
| Modelica.Units.SI.SpecificHeatCapacity | cp | 3200 | specific heat of the coolant |
| Integer | n_isol_f | 5 | number of front face meshes |
| Integer | n_stock | 5 | number of stock meshes |
| Integer | n_isol_b | 3 | number of back side meshes |
| Modelica.Units.SI.Length | e_isol_f | 0.16 | front face insulation thickness |
| Modelica.Units.SI.Length | e_isol_b | 0.03 | back face insulation thickness |
| Modelica.Units.SI.Length | e_stock | 0.2 | stock thickness |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Blocks.Interfaces.RealInput | G | ||
| BaseClasses.HeatTransfer.Interfaces.HeatPort_a | Tf | front panel temperature | |
| BaseClasses.HeatTransfer.Interfaces.HeatPort_b | Tb | back panel temperature | |
| Modelica.Blocks.Interfaces.BooleanInput | ON |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.Temperature[n] | T | vector of fluid temperatures on the capture surface side | |
| Modelica.Units.SI.Temperature[n] | Tem | vector of fluid temepratures on the emission side |