modelZonalFlow_ACS
Zonal flow with input air change per second
Extends from BuildingSystems.Airflow.Multizone.BaseClasses.ZonalFlow.
Information
This model computes the air exchange between volumes.
Input is the air change per seconds. The volume flow rate is computed as
V_flow = ACS * V
where ACS is an input and the volume V is a parameter.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Boolean | useDefaultProperties | false | Set to true to use constant density |
| Modelica.Units.SI.Volume | V | Volume of room |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Blocks.Interfaces.RealInput | ACS | Air change per seconds, relative to the smaller of the two volumes |
Revisions
-
August 18, 2014, by Michael Wetter:
Removed parameterforceErrorControlOnFlowas it was not used. Changed message of assert statement to avoid an error in OpenModelica. -
October 8, 2013 by Michael Wetter:
Changed the parameteruseConstantDensitytouseDefaultPropertiesto use consistent names within this package. A conversion script can be used to update this parameter. -
December 14, 2012 by Michael Wetter:
Renamed protected parameters for consistency with the naming conventions. -
July 20, 2010 by Michael Wetter:
Migrated model to Modelica 3.1 and integrated it into the Buildings library. -
January 4, 2006 by Michael Wetter:
Implemented first version.