modelBuilding1Zone1DBox

1 zone thermal building model with the shape of a box

Extends from BuildingSystems.Buildings.BaseClasses.BuildingTemplate.

Information

This is a 1 zone thermal building model with the shape of a box.

Parameters

TypeNameDefaultDescription
Opaque constructions › Exterior constructions
BuildingSystems.Buildings.Data.Constructions.OpaqueThermalConstructionconstructionWall1Data of the thermal construction
BuildingSystems.Buildings.Data.Constructions.OpaqueThermalConstructionconstructionWall2Data of the thermal construction
BuildingSystems.Buildings.Data.Constructions.OpaqueThermalConstructionconstructionWall3Data of the thermal construction
BuildingSystems.Buildings.Data.Constructions.OpaqueThermalConstructionconstructionWall4Data of the thermal construction
BuildingSystems.Buildings.Data.Constructions.OpaqueThermalConstructionconstructionCeilingData of the thermal construction
BuildingSystems.Buildings.Data.Constructions.OpaqueThermalConstructionconstructionBottomData of the thermal construction
Opaque constructions › Interior constructions
BooleanInteriorWallstrueTrue: Interior walls are present, false: Interior walls are absent
Modelica.Units.SI.AreaAInteriorWalls1.0Surface area of one side of the interior walls
BuildingSystems.Buildings.Data.Constructions.OpaqueThermalConstructionconstructionWallsInteriorData of the thermal construction
BooleanInteriorCeilingstrueTrue: Interior ceilings are present, false: Interior ceilings are absent
Modelica.Units.SI.AreaAInteriorCeilings1.0Surface area of one side of the interior ceilings
BuildingSystems.Buildings.Data.Constructions.OpaqueThermalConstructionconstructionCeilingsInteriorData of the thermal construction
Opaque constructions › Thermal boundary conditions
BuildingSystems.Buildings.Types.ThermalBoundaryConditionBCWall1BuildingSystems.Buildings.Types.ThermalBoundaryCondition.AmbienceThermal boundary condition wall1
Modelica.Units.SI.TemperatureTWall1_constant293.15Constant temperature on the outer surface of wall1 (used if BCWall1=Constant)
BuildingSystems.Buildings.Types.ThermalBoundaryConditionBCWall2BuildingSystems.Buildings.Types.ThermalBoundaryCondition.AmbienceThermal boundary condition wall2
Modelica.Units.SI.TemperatureTWall2_constant293.15Constant temperature on the outer surface of wall2 (used if BCWall2=Constant)
BuildingSystems.Buildings.Types.ThermalBoundaryConditionBCWall3BuildingSystems.Buildings.Types.ThermalBoundaryCondition.AmbienceThermal boundary condition wall3
Modelica.Units.SI.TemperatureTWall3_constant293.15Constant temperature on the outer surface of wall3 (used if BCWall3=Constant)
BuildingSystems.Buildings.Types.ThermalBoundaryConditionBCWall4BuildingSystems.Buildings.Types.ThermalBoundaryCondition.AmbienceThermal boundary condition wall4
Modelica.Units.SI.TemperatureTWall4_constant293.15Constant temperature on the outer surface of wall4 (used if BCWall4=Constant)
BuildingSystems.Buildings.Types.ThermalBoundaryConditionBCCeilingBuildingSystems.Buildings.Types.ThermalBoundaryCondition.AmbienceThermal boundary condition ceiling
Modelica.Units.SI.TemperatureTCeiling_constant293.15Constant temperature on the outer surface of ceiling (used if BCCeiling=Constant)
General › Geometry
Modelica.Units.SI.Lengthwidth10.0Width of the building (inner space)
Modelica.Units.SI.Lengthlength10.0Length of the building (inner space)
Modelica.Units.SI.Lengthheight2.8Height of the building (inner space)
Transparent constructions › window1 (included in constructionWall1)
Modelica.Units.SI.LengthwidthWindow10.0Width of window1
Modelica.Units.SI.LengthheightWindow10.0Height of window1
RealframePortionWindow10.2Frame portion of window1
BuildingSystems.Buildings.Data.Constructions.TransparentConstructionconstructionWindow1Data of the construction of window1
Booleanuse_GSCWindow1_infalse= true, use input for geometric shading coefficient GSCWindow1
Transparent constructions › window2 (included in constructionWall2)
Modelica.Units.SI.LengthwidthWindow20.0Width of window2
Modelica.Units.SI.LengthheightWindow20.0Height of window2
RealframePortionWindow20.2Frame portion of window2
BuildingSystems.Buildings.Data.Constructions.TransparentConstructionconstructionWindow2Data of the construction of window2
Booleanuse_GSCWindow2_infalse= true, use input for geometric shading coefficient GSCWindow2
Transparent constructions › window3 (included in constructionWall3)
Modelica.Units.SI.LengthwidthWindow30.0Width of window3
Modelica.Units.SI.LengthheightWindow30.0Height of window3
RealframePortionWindow30.2Frame portion of window3
BuildingSystems.Buildings.Data.Constructions.TransparentConstructionconstructionWindow3Data of the construction of window3
Booleanuse_GSCWindow3_infalse= true, use input for geometric shading coefficient GSCWindow2
Transparent constructions › window4 (included in constructionWall4)
Modelica.Units.SI.LengthwidthWindow40.0Width of window4
Modelica.Units.SI.LengthheightWindow40.0Height of window4
RealframePortionWindow40.2Frame portion of window4
BuildingSystems.Buildings.Data.Constructions.TransparentConstructionconstructionWindow4Data of the construction of window4
Booleanuse_GSCWindow4_infalse= true, use input for geometric shading coefficient GSCWindow4
Initialization › Opaque constructions
Modelica.Units.SI.TemperatureTWall1_start293.15Start temperature of each layer of wall1
Modelica.Units.SI.TemperatureTWall2_start293.15Start temperature of each layer of wall2
Modelica.Units.SI.TemperatureTWall3_start293.15Start temperature of each layer of wall3
Modelica.Units.SI.TemperatureTWall4_start293.15Start temperature of each layer of wall4
Modelica.Units.SI.TemperatureTCeiling_start293.15Start temperature of each layer of ceiling
Modelica.Units.SI.TemperatureTBottom_start293.15Start temperature of each layer of bottom
Modelica.Units.SI.TemperatureTWallsInterior_start293.15Start temperature of each layer of interior walls
Modelica.Units.SI.TemperatureTCeilingsInterior_start293.15Start temperature of each layer of interior ceilings
Initialization › Transparent constructions
Modelica.Units.SI.TemperatureTWindow1_start293.15Start temperature of each layer of window1
Modelica.Units.SI.TemperatureTWindow2_start293.15Start temperature of each layer of window2
Modelica.Units.SI.TemperatureTWindow3_start293.15Start temperature of each layer of window3
Modelica.Units.SI.TemperatureTWindow4_start293.15Start temperature of each layer of window4
Initialization
Modelica.Units.SI.TemperatureTAir_start293.15Start temperature of indoor air temperature
Advanced › Thermal comfort (PMV and PPD calculation)
Realclo0.5Clothing
Realmet1.2Metabolism rate
Modelica.Units.SI.VelocityvAir0.1Mean relative air velocity in the area of user presence
Advanced › Numerical Parameters
BuildingSystems.Buildings.Types.NumericalResolutionnumResWall1BuildingSystems.Buildings.Types.NumericalResolution.LowNumerical resolution wall1
BuildingSystems.Buildings.Types.NumericalResolutionnumResWall2BuildingSystems.Buildings.Types.NumericalResolution.LowNumerical resolution wall2
BuildingSystems.Buildings.Types.NumericalResolutionnumResWall3BuildingSystems.Buildings.Types.NumericalResolution.LowNumerical resolution wall3
BuildingSystems.Buildings.Types.NumericalResolutionnumResWall4BuildingSystems.Buildings.Types.NumericalResolution.LowNumerical resolution wall4
BuildingSystems.Buildings.Types.NumericalResolutionnumResCeilingBuildingSystems.Buildings.Types.NumericalResolution.LowNumerical resolution ceiling
BuildingSystems.Buildings.Types.NumericalResolutionnumResBottomBuildingSystems.Buildings.Types.NumericalResolution.LowNumerical resolution bottom
BuildingSystems.Buildings.Types.NumericalResolutionnumResCeilingsInteriorBuildingSystems.Buildings.Types.NumericalResolution.LowNumerical resolution interior ceilings
BuildingSystems.Buildings.Types.NumericalResolutionnumResWallsInteriorBuildingSystems.Buildings.Types.NumericalResolution.LowNumerical resolution interior walls

Components

TypeNameDefaultDescription
BuildingSystems.Buildings.Surfaces.SurfaceToSolidouterSurfaceWall1Surface for outer thermal boundary condition of wall1
Modelica.Thermal.HeatTransfer.Sources.FixedTemperatureConstTempWall1Constant temperature on the outer surface of wall1
BuildingSystems.Buildings.Surfaces.SurfaceToSolidouterSurfaceWall2Surface for outer thermal boundary condition of wall2
Modelica.Thermal.HeatTransfer.Sources.FixedTemperatureConstTempWall2Constant temperature on the outer surface of wall2
BuildingSystems.Buildings.Surfaces.SurfaceToSolidouterSurfaceWall3Surface for outer thermal boundary condition of wall3
Modelica.Thermal.HeatTransfer.Sources.FixedTemperatureConstTempWall3Constant temperature on the outer surface of wall3
BuildingSystems.Buildings.Surfaces.SurfaceToSolidouterSurfaceWall4Surface for outer thermal boundary condition of wall4
Modelica.Thermal.HeatTransfer.Sources.FixedTemperatureConstTempWall4Constant temperature on the outer surface of wall4
BuildingSystems.Buildings.Surfaces.SurfaceToSolidouterSurfaceCeilingSurface for outer thermal boundary condition of ceiling
Modelica.Thermal.HeatTransfer.Sources.FixedTemperatureConstTempCeilingConstant temperature on the outer surface of ceiling
Modelica.Blocks.Interfaces.RealOutputGSCWindow1_constant0.0Constant shading coefficient window1 (if use_GSCWindow1_in = true)
Modelica.Blocks.Interfaces.RealInputGSCWindow1_inShading coefficient window1
Modelica.Blocks.Interfaces.RealOutputGSCWindow2_constant0.0Constant shading coefficient window1 (if use_GSCWindow2_in = true)
Modelica.Blocks.Interfaces.RealInputGSCWindow2_inShading coefficient window2
Modelica.Blocks.Interfaces.RealOutputGSCWindow3_constant0.0Constant shading coefficient window1 (if use_GSCWindow3_in = true)
Modelica.Blocks.Interfaces.RealInputGSCWindow3_inShading coefficient window3
Modelica.Blocks.Interfaces.RealOutputGSCWindow4_constant0.0Constant shading coefficient window4 (if use_GSCWindow4_in = true)
Modelica.Blocks.Interfaces.RealInputGSCWindow4_inShading coefficient window4
Modelica.Blocks.Interfaces.RealInputwme0.0External work
BuildingSystems.Buildings.Zones.ZoneTemplateAirvolumeMixedzoneThermal zone
BuildingSystems.Buildings.Constructions.Walls.WallThermal1DNodeswall1Wall 1 (west oriented if angleDegAzi is 0 degree)
BuildingSystems.Buildings.Constructions.Walls.WallThermal1DNodeswall2Wall 2 (north oriented if angleDegAzi is 0 degree)
BuildingSystems.Buildings.Constructions.Walls.WallThermal1DNodeswall3Wall 3 (east oriented if angleDegAzi is 0 degree)
BuildingSystems.Buildings.Constructions.Walls.WallThermal1DNodeswall4Wall 4 (south oriented if angleDegAzi is 0 degree)
BuildingSystems.Buildings.Constructions.Walls.WallThermal1DNodesceilingCeiling (horizontal oriented)
BuildingSystems.Buildings.Constructions.Walls.WallThermal1DNodesbottomBottom
BuildingSystems.Buildings.Constructions.Walls.WallThermal1DNodeswallsInteriorOptional interior walls
BuildingSystems.Buildings.Constructions.Walls.WallThermal1DNodesceilingsInteriorOptional interior ceilings
BuildingSystems.Buildings.Constructions.Windows.Windowwindow1Window 1 (west oriented if angleDegAzi is 0 degree)
BuildingSystems.Buildings.Constructions.Windows.Windowwindow2Window 2 (north oriented if angleDegAzi is 0 degree)
BuildingSystems.Buildings.Constructions.Windows.Windowwindow3Window 3 (east oriented if angleDegAzi is 0 degree)
BuildingSystems.Buildings.Constructions.Windows.Windowwindow4Window 4 (south oriented if angleDegAzi is 0 degree)

Revisions

  • February 4, 2020 by Christoph Nytsch-Geusen:
    Thermal comfort assessment added
  • January 25, 2018 by Christoph Nytsch-Geusen:
    Adaptation to new zone model.
  • May 23, 2015 by Christoph Nytsch-Geusen:
    First implementation.