modelElectricalModelOneDiodeGeneral
Basic electrical one diode model of a PV module
Extends from BuildingSystems.Technologies.Photovoltaics.BaseClasses.ElectricalModels.ElectricalModelGeneral.
Information
This is a basic electrical one diode model of a PV module.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.ElectricCurrent | Ik0 | Short circuit current under standard conditions | |
| Modelica.Units.SI.Voltage | Ul0 | Open circuit voltage under standard conditions | |
| Real | tIk0 | Temperature coefficient for the short circuit current | |
| Real | tUl0 | Temperature coefficient for the open circuit voltage | |
| Real | factor | Scaling factor adaptation to the complex PV cell model | |
| Modelica.Units.SI.LinearTemperatureCoefficient | alphaIk | 0.001*tIk0/Ik0 | Specific temperature coefficient for the short circuit |
| Modelica.Units.SI.LinearTemperatureCoefficient | alphaUl | tUl0/Ul0 | Specific temperature coefficient for the open circuit |
| Real | c0 | (Ik0/nCelPar)/1000.0 | Coefficient for the photo current |
| Real | m1 | 1.0 | Diode factor |
| Real | NANO | 1.0e-9 |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.ElectricCurrent | IPho | Photo current | |
| Real | ISat1 | Saturation current nA | |
| Modelica.Units.SI.Voltage | Ul | Open circuit voltage |
Revisions
-
March 1, 2015 by Christoph Nytsch-Geusen:
First implementation.