recordCollectorPartial
Extends from Modelica.Icons.Record.
Information
Record model with important data about solar thermal collectors.
Assumption and limitations
The exact contribution of the structure/solid part of the solar collector to its effective thermal capacity is set to 5 kJ/K pro square meter of absorber area.
References
Information about solar collectors can be consulted in SPF
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | C_0 | Collector constant in [-] | |
| Real | C_1 | Collector constant in W/(m2.K) | |
| Real | C_2 | Collector constant in W/(m2*K.2) | |
| Real | IAMC | Incidence Angle Modifier Coefficient = IncidenceAngleModifier at 50 degree | |
| Real | C_A | 500*10 | Active heat capacity of the solid part of the collector per square meter of absorber surface in J/m2K |
| Geometry | |||
| Real | V_A | (fluid Volume)/(absorber area) rate | |
| Modelica.Units.SI.Area | A | Absorber area of the collector | |