modelVDI6007WithWindow

Equivalent air temperature as defined in VDI 6007 Part 1 with modifications

Extends from BaseClasses.PartialVDI6007.

Information

This model is a variant of the calculations defined in VDI 6007 Part 1. It adds a second equivalent air temperature for windows in case heat transfer through windows and exterior walls is handled separately in the Reduced Order Model. The sum of all weightfactors for windows should be one as well as the sum for all wall elements.

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.CoefficientOfHeatTransferhConWinOutWindows' convective coefficient of heat transfer (outdoor)

Components

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealOutputTEqAirWinEquivalent air temperature for windows (no short-wave radiation)

Revisions

  • May 5, 2023, by Philip Groesdonk:
    Added an option for non-constant ground temperature from an input connector. This is for #1744.
  • July 11, 2019, by Katharina Brinkmann:
    Renamed alphaWinOut to hConWinOut
  • September 26, 2016, by Moritz Lauster:
    Moved calculations to BuildingSystems.ThermalZones.ReducedOrder.EquivalentAirTemperature.BaseClasses.PartialVDI6007.
  • September 2015, by Moritz Lauster:
    Got rid of cardinality and used assert for warnings.
    Adapted to Annex 60 requirements.
  • October 2014, by Peter Remmen:
    Implemented.