modelController
Validation of the top-level controller
Information
This example validates Buildings.Controls.OBC.ASHRAE.G36.AHUs.SingleZone.VAV.Controller.
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Buildings.Controls.OBC.ASHRAE.G36.AHUs.SingleZone.VAV.Controller | conVAV | Validate the cooling case | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Ramp | TZon | Measured zone temperature | |
| Buildings.Controls.SetPoints.OccupancySchedule | occSch | Occupancy schedule | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | TOut | Outdoor air dry bulb temperature | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | cooDowTim | Cooling down time | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | warUpTim | Warm-up time | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Sin | cooSetAdj | Cooling setpoint adjustment | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Sin | heaSetAdj | Heating setpoint adjustment | |
| Buildings.Controls.OBC.CDL.Logical.Sources.Pulse | winSta | Generate signal indicating window status | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | zerAdj | Zero adjustment | |
| Buildings.Controls.OBC.CDL.Reals.Switch | swi1 | Switch to zero adjustment when window is open | |
| Buildings.Controls.OBC.CDL.Reals.Switch | swi2 | Switch to zero adjustment when window is open | |
| Buildings.Controls.OBC.CDL.Logical.Sources.Pulse | occSta | Generate signal indicating occupancy status | |
| Buildings.Controls.OBC.CDL.Integers.Sources.Constant | demLimLev | Demand limit level | |
| Buildings.Controls.OBC.CDL.Logical.Sources.Pulse | freRes | Freeze protection reset | |
| Buildings.Controls.OBC.CDL.Logical.Not | not1 | Logical not | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Ramp | mixTem | Mixed air temperature | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Ramp | outDam | Outdoor damper position | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Ramp | cooCoi | Cooling coil position | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | heaCoi | Heating coil position | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Ramp | TSup | Terminal unit discharge air temperature | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | THeaSetOcc | Occupied heating setpoint | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | TCooSetOcc | Occupied cooling setpoint | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | THeaSetUno | Unoccupied heating setpoint | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | TCooSetUno | Unoccupied cooling setpoint | |
| CDL.Logical.Not | not2 | Logical not |
Revisions
-
February 9, 2022, by Jianjun Hu:
First implementation.