blockSupplyAirTemperature
Validation model for supply air temperature setpoint subsequence
Information
This example validates Buildings.Controls.OBC.ASHRAE.G36.FanCoilUnits.Subsequences.SupplyAirTemperature. Each of the four instances of the controller represents operation with different inputs for heating and cooling loop signals, and different configuration parameters of fan coil unit with presence or absence of heating and cooling coils, as described in the instance comments.
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Buildings.Controls.OBC.ASHRAE.G36.FanCoilUnits.Subsequences.SupplyAirTemperature | TSupAir | Instance demonstrating heating signal operation | |
| Buildings.Controls.OBC.ASHRAE.G36.FanCoilUnits.Subsequences.SupplyAirTemperature | TSupAir3 | Instance demonstrating cooling signal operation when heating coil is absent | |
| Buildings.Controls.OBC.ASHRAE.G36.FanCoilUnits.Subsequences.SupplyAirTemperature | TSupAir2 | Instance demonstrating heating signal operation when cooling coil is absent | |
| Buildings.Controls.OBC.ASHRAE.G36.FanCoilUnits.Subsequences.SupplyAirTemperature | TSupAir1 | Instance demonstrating cooling signal operation | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Sin | sin | Supply air temperature signal | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Sin | sin3 | Supply air temperature signal | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Sin | sin5 | Cooling loop signal | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Sin | sin6 | Supply air temperature signal | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Sin | sin8 | Heating loop signal | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Sin | sin4 | Supply air temperature signal | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | con | Zone heating temperature setpoint | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | con1 | Zone cooling temperature setpoint | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | con2 | Zone heating temperature setpoint | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | con3 | Zone cooling temperature setpoint | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | con4 | Zone heating temperature setpoint | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | con6 | Zone cooling temperature setpoint | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | con5 | Heating loop signal | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | con7 | Heating loop signal | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | con8 | Cooling loop signal | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | con9 | Cooling loop signal | |
| Buildings.Controls.OBC.CDL.Logical.Sources.Constant | con10 | Boolean fale signal |
Revisions
-
March 18, 2022, by Karthik Devaprasad:
First implementation.