modelCollectorDistributor
Model of a collector/distributor with zero pressure drop between connections
Extends from Buildings.DHC.Networks.BaseClasses.PartialDistribution2Pipe.
Information
This model represents a collector/distributor which connects
nCon hydronic circuits in parallel.
The pressure drop between each connection is assumed negligible
compared to the pressure drop in each circuit, and is set to zero
in the model.
By default,
-
there is no bypass flow (which can be added later by connecting
the ports
port_bDisSupandport_aDisRet), -
the nominal distribution mass flow rate
mDis_flow_nominalis equal to the sum of the nominal mass flow rate in each circuit. However, this parameter assigment is not final and it can be set for instance to a higher value to represent a primary overflow in a supply through loop.
Revisions
-
July 31, 2020, by Antoine Gautier:
First implementation.