modelICT
This is the simulation model of ICT within building OfficeBuilding
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Buildings.BoundaryConditions.SolarIrradiation.DiffusePerez[6] | HDifTil | Calculates diffuse solar radiation on titled surface for all directions | |
| Buildings.BoundaryConditions.SolarIrradiation.DirectTiltedSurface[6] | HDirTil | Calculates direct solar radiation on titled surface for all directions | |
| Buildings.ThermalZones.ReducedOrder.SolarGain.CorrectionGDoublePane | corGDoublePane | Correction factor for solar transmission | |
| Buildings.ThermalZones.ReducedOrder.RC.TwoElements | thermalZoneTwoElements | Thermal zone | |
| Buildings.ThermalZones.ReducedOrder.EquivalentAirTemperature.VDI6007WithWindow | eqAirTemp | Computes equivalent air temperature | |
| Modelica.Blocks.Math.Add[6] | solRad | Sums up solar radiation of both directions | |
| Modelica.Thermal.HeatTransfer.Sources.PrescribedTemperature | prescribedTemperature | Prescribed temperature for exterior walls outdoor surface temperature | |
| Modelica.Thermal.HeatTransfer.Sources.PrescribedTemperature | prescribedTemperature1 | Prescribed temperature for windows outdoor surface temperature | |
| Modelica.Thermal.HeatTransfer.Components.Convection | thermalConductorWin | Outdoor convective heat transfer of windows | |
| Modelica.Thermal.HeatTransfer.Components.Convection | thermalConductorWall | Outdoor convective heat transfer of walls | |
| Modelica.Blocks.Sources.Constant[6] | const | Sets sunblind signal to zero (open) | |
| Buildings.BoundaryConditions.WeatherData.Bus | weaBus | Weather data bus | |
| Modelica.Blocks.Sources.Constant | hConWall | Outdoor coefficient of heat transfer for walls | |
| Modelica.Blocks.Sources.Constant | hConWin | Outdoor coefficient of heat transfer for windows | |
| Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow | personsRad | Radiative heat flow of persons | |
| Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow | personsConv | Convective heat flow of persons | |
| Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow | machinesConv | Convective heat flow of machines | |
| Modelica.Blocks.Sources.CombiTimeTable | internalGains | Table with profiles for persons (radiative and convective) and machines (convective) | |
| Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a | port_a | Heat port for sensible convective gains | |
| Buildings.Controls.OBC.CDL.Interfaces.RealOutput | TAir | Room air temperature |