recordValidationData1
Validation data set 1
Extends from Buildings.Fluid.CHPs.Data.Generic.
Information
This is the record of parameters for CHP models derived from the parameters of
EnergyPlus example MicroCogeneration, with following changes:
- changed the condition of the warm-up mode, from depending on the time delay to engine temperature.
-
changed the minimum cooling water flow rate
mWatMin_flowfrom 0 to 0.1 kg/s. -
limited the maximum rate of change in the power output
dPEleMaxand the maximum rate of change in the fuel mass flow ratedmFueMax_flow, by reducing from 1e+9 to 200 and from 1e+9 to 2 respectively. -
changed electric power consumptions during standby
PStaByand cool-downPCooDowmode from 0 W to 100 W and 200 W respectively.
Revisions
-
March 08, 2019, by Tea Zakula:
First implementation.