recordValidationData1

Validation data set 1

Extends from Buildings.Fluid.CHPs.Data.Generic.

Information

This is the record of parameters for CHP models derived from the parameters of EnergyPlus example MicroCogeneration, with following changes:

  • changed the condition of the warm-up mode, from depending on the time delay to engine temperature.
  • changed the minimum cooling water flow rate mWatMin_flow from 0 to 0.1 kg/s.
  • limited the maximum rate of change in the power output dPEleMax and the maximum rate of change in the fuel mass flow rate dmFueMax_flow, by reducing from 1e+9 to 200 and from 1e+9 to 2 respectively.
  • changed electric power consumptions during standby PStaBy and cool-down PCooDow mode from 0 W to 100 W and 200 W respectively.

Revisions

  • March 08, 2019, by Tea Zakula:
    First implementation.