modelInfiniteLineSource
Test case for infinite line source
Extends from Modelica.Icons.Example.
Information
This example demonstrates the use of the function for the evaluation of the infinite line source solution.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.ThermalDiffusivity | aSoi | 1.0e-6 | Ground thermal diffusivity |
| Modelica.Units.SI.Radius | rSource | 0.075 | Minimum radius |
| Modelica.Units.SI.Radius | r | {rSource, 2*rSource, 5*rSource, 10*rSource, 20*rSource} | Radial position of evaluation of the solution |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.Time | t | Time | |
| Real | E | Infinite line source solution |
Revisions
-
June 12, 2018, by Massimo Cimmino:
First implementation.