modelCoils
Validation model for coil components
Extends from Modelica.Icons.Example.
Information
This model validates the models within Buildings.Templates.Components.Coils by exposing them to a fixed pressure difference on the air side. Models representing a water-based coil with valve are also exposed to a fixed pressure difference on the water side, and a varying valve opening from fully closed to fully open position. Other coil models are controlled with a signal varying from 0 to 1.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Dynamics › Conservation equations | |||
| Modelica.Fluid.Types.Dynamics | energyDynamics | Modelica.Fluid.Types.Dynamics.FixedInitial | Type of energy balance: dynamic (3 initialization options) or steady state |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Fluid.Sources.Boundary_pT | bouAirEntCoo | Boundary conditions for entering air | |
| Fluid.Sources.Boundary_pT | bouChiWatEnt | Boundary conditions for entering CHW | |
| Fluid.Sources.Boundary_pT | bouLiqLvg | Boundary conditions for leaving liquid | |
| Fluid.Sources.Boundary_pT | bouAirLvg | Boundary conditions for leaving air | |
| Buildings.Templates.Components.Coils.WaterBasedCooling | coiCoo | Water-based cooling coil | |
| Interfaces.Bus | bus | Control bus | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Ramp | y | Coil/valve control signal | |
| Buildings.Templates.Components.Coils.WaterBasedHeating | coiHea | Water-based heating | |
| Interfaces.Bus | bus1 | Control bus | |
| Fluid.Sources.Boundary_pT | bouAirEntHea | Boundary conditions for entering air | |
| Fluid.Sources.Boundary_pT | bouHeaWatEnt | Boundary conditions for entering HW | |
| Buildings.Templates.Components.Coils.ElectricHeating | coiEle | Electric heating | |
| Interfaces.Bus | bus2 | Control bus | |
| Buildings.Templates.Components.Coils.EvaporatorVariableSpeed | coiEva | Variable speed evaporator coil | |
| BoundaryConditions.WeatherData.Bus | weaBus | Weather data bus | |
| Interfaces.Bus | bus3 | Control bus | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | TOut | Outdoor temperature | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | XOut | Water mass fraction in outdoor air | |
| Buildings.Utilities.Psychrometrics.TWetBul_TDryBulXi | wetBul | Compute wet bulb temperature | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | pOut | Outdoor pressure | |
| Fluid.Sources.Boundary_pT | bouAirEntCoo1 | Boundary conditions for entering air | |
| Buildings.Utilities.Psychrometrics.X_pTphi | x_pTphi | Compute wet bulb temperature | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | TAirEnt | Entering air temperature | |
| Buildings.Controls.OBC.CDL.Reals.Sources.Constant | phiAirEnt | Enetring air relative humidity | |
| Buildings.Templates.Components.Coils.EvaporatorMultiStage | coiMul | Multiple stage evaporator coil | |
| Buildings.Controls.OBC.CDL.Integers.Sources.TimeTable | y1 | Coil/valve control signal | |
| Interfaces.Bus | bus4 | Control bus | |
| Fluid.FixedResistances.PressureDrop | res | Flow resistance | |
| Buildings.Templates.Components.Coils.None | non | No coilamper |
Contents
| Name | Description |
|---|---|
| MediumAir | |
| MediumLiq |