modelConstruction
Model for an opaque construction that has no window
Extends from Buildings.ThermalZones.Detailed.Constructions.BaseClasses.PartialConstruction.
Information
This model is used to compute heat transfer through opaque constructions inside the room model. The model uses the recordlayers to access the material properties
of the opaque construction. The heat transfer is computed in the instance
opa, which uses the model
Buildings.HeatTransfer.Conduction.MultiLayer.Revisions
-
December 6 2010, by Michael Wetter: