modelCloset

Model of the closet connected to test cell X3A

Extends from Buildings.ThermalZones.Detailed.MixedAir.

Information

This is a model for the closet attached to test cell 3A in the LBNL User Facility. This documentation describes the wall constructions used in the closet. Documentation describing how it should be connected to other models in the package to form a complete model of test cell X3A can be found in Buildings.ThermalZones.Detailed.FLEXLAB.Rooms.X3A.

There are four different wall sections connected to the closet modeled here. They are shown in the figure below.

Wall sections in Closet model

The different wall sections are represented in the model according to the following table.

Wall Section Number Description Location in Model Corresponding Layer
1 North wall on the exterior of the buildings datConExt[1] higIns
2 East wall connected to ThermalZones.Detailed.FLEXLAB.Rooms.X3B.Closet datConBou[2] celDiv
3 Air space connected to partition wall and door in TestCell model Wall: datSurBou[1]
Door: datSurBou[2]
4 West wall connected to Electrical datConBou[1] higIns

There are two additional surfaces which are not included in the diagram. One is the model of the roof. It is modeled in datConExt[2] using the layer roo. The other is the floor, which is modeled in datConBou[1] using the layer slaCon.

Several of the connections in this model are intended to be connected to specific surfaces in other room models. The following table describes the connections to models outside of the X3A package.. The connections in datConExt are not described in the table because they are connected to the external environment, and no additional heat port connections are necessary. A rationale for why the model is created this way is also provided if it is considered necessary.

Location in Closet Description of External Connection Location in External Model Rationale
surf_conBou[2] X3B.Closet References a data table A data table is used, instead of a model of ThermalZones.Detailed.FLEXLAB.Rooms.X3B.Closet, because the goal of this model is to be able to perform simulations of TestCell with minimal complexity, by simplifying the neighboring test cells. The wall separating the test cells is highly insulated, and it is believed that the error in simulations caused by using a data table will be negligible.
surf_conBou[3] Ground temperature There is no specific connection which is appropriate connection for this construction. surf_conBou[3] represents the floor of the room, and must be connected to a heat port representing the ground temperature.

Parameters

TypeNameDefaultDescription
Data.Constructions.OpaqueConstructions.DividingWalls.CellAndElectricalDividingWallhigInsHigh insulation wall. Between X3A closet and exterior, X3A closet and electrical room
Data.Constructions.OpaqueConstructions.DividingWalls.TestCellDividngWallcelDivWall dividing the X3A closet and the X3B closet
Data.Constructions.OpaqueConstructions.Roofs.ASHRAE_901_2010RoofrooConstruction of the roof of the closet in X3A
HeatTransfer.Data.OpaqueConstructions.GenericslaConConstruction of the slab

Revisions

  • Sept 16, 2013 by Peter Grant:
    Added a model representing the floor.
  • July 26, 2013 by Peter Grant:
    First implementation.