modelInteriorWall

Model of an interior wall with Spawn-controlled surface conditions

Extends from Buildings.HeatTransfer.Conduction.BaseClasses.PartialConstruction.

Information

This is a model of the heat transfer through an interior wall, which is connected to an EnergyPlus Zone Heat Balance through Buildings.ThermalZones.EnergyPlus_24_2_0.ZoneSurface objects on both side of the wall.

This model can be used in a Spawn simulation to substitute the heat conduction calculation performed by EnergyPlus with a Buildings.HeatTransfer.Conduction.MultiLayer object.

Parameters

TypeNameDefaultDescription
StringsurNam_aName of EnergyPlus Surface (port a)
StringsurNam_bName of EnergyPlus Surface (port b)
Modelica.Units.SI.AreaAWall area
Buildings.HeatTransfer.Data.OpaqueConstructions.GenericlayersConstruction definition from Data.OpaqueConstructions

Components

TypeNameDefaultDescription
Buildings.ThermalZones.EnergyPlus_24_2_0.ZoneSurfacesur_aWall surface (port a)
Buildings.ThermalZones.EnergyPlus_24_2_0.ZoneSurfacesur_bWall surface (port b)
Buildings.HeatTransfer.Conduction.MultiLayerwalConWall conduction
Modelica.Thermal.HeatTransfer.Sensors.TemperatureSensorTSur_aSurface temperature (port a)
Buildings.HeatTransfer.Sources.PrescribedHeatFlowheaSur_aSurface heat transfer rate (port a)
Modelica.Thermal.HeatTransfer.Sensors.TemperatureSensorTSur_bSurface temperature (port b)
Buildings.HeatTransfer.Sources.PrescribedHeatFlowheaSur_bSurface heat transfer rate (port b)

Revisions

  • July 21, 2021, by Baptiste Ravache:
    First implementation.