modelBoundaryGas_pTxi

A gas source defining pressure, Temperature and composition
Diagram of BoundaryGas_pTxi

Extends from ClaRa.Basics.Icons.FlowSink.

Information

For detailed model documentation please consult the html-documentation shipped with ClaRa.

 


Authorship and Copyright Statement for original (initial) Contribution

Author:

DYNCAP/DYNSTART development team, Copyright © 2011-2024.

References:

For references please consult the html-documentation shipped with ClaRa.

Remarks:

This component was developed by ClaRa development team under the 3-clause BSD License.

Acknowledgements:

ClaRa originated from the collaborative research projects DYNCAP and DYNSTART. Both research projects were supported by the German Federal Ministry for Economic Affairs and Energy (FKZ 03ET2009 and FKZ 03ET7060).

CLA:

The author(s) have agreed to ClaRa CLA, version 1.0. See https://claralib.com/pdf/CLA.pdf

By agreeing to ClaRa CLA, version 1.0 the author has granted the ClaRa development team a permanent right to use and modify his initial contribution as well as to publish it or its modified versions under the 3-clause BSD License.

The ClaRa development team consists of the following partners:

TLK-Thermo GmbH (Braunschweig, Germany)

XRG Simulation GmbH (Hamburg, Germany).

Parameters

TypeNameDefaultDescription
Summary and Visualisation
BooleancontributeToCycleSummarysimCenter.contributeToCycleSummaryTrue if component shall contribute to automatic efficiency calculation
IntegerenergyType0Type of energy
Fundamental Definitions
TILMedia.Gas.Types.BaseGasmediumsimCenter.flueGasModelMedium to be used in tubes
Define Variable Boundaries
Booleanvariable_pfalseTrue, if pressure defined by variable input
Booleanvariable_TfalseTrue, if spc. temperature defined by variable input
Booleanvariable_xifalseTrue, if composition defined by variable input
Constant Boundaries
ClaRa.Basics.Units.Pressurep_constsimCenter.p_amb_startConstant pressure
ClaRa.Basics.Units.TemperatureT_constsimCenter.T_amb_startConstant specific temperature of source
ClaRa.Basics.Units.MassFraction[medium.nc - 1]xi_constmedium.xi_defaultConstant composition

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInputpp_inVariable mass flow rate
Modelica.Blocks.Interfaces.RealInputTT_inVariable specific temperature
Modelica.Blocks.Interfaces.RealInput[medium.nc - 1]xixi_inVariable composition
ClaRa.Basics.Interfaces.GasPortIngas_a
Basics.Interfaces.EyeOutGaseyeOut

Components

TypeNameDefaultDescription
ClaRa.Basics.Interfaces.Connected2SimCenterconnected2SimCenter
ClaRa.SimCentersimCenter