modelFeedForwardBlock_3508
Information
For detailed model documentation please consult the html-documentation shipped with ClaRa.
Authorship and Copyright Statement for original (initial) Contribution
Author:
DYNCAP/DYNSTART development team, Copyright © 2011-2024.References:
For references please consult the html-documentation shipped with ClaRa.
Remarks:
This component was developed by ClaRa development team under the 3-clause BSD License.
Acknowledgements:ClaRa originated from the collaborative research projects DYNCAP and DYNSTART. Both research projects were supported by the German Federal Ministry for Economic Affairs and Energy (FKZ 03ET2009 and FKZ 03ET7060).
CLA:
The author(s) have agreed to ClaRa CLA, version 1.0. See https://claralib.com/pdf/CLA.pdf
By agreeing to ClaRa CLA, version 1.0 the author has granted the ClaRa development team a permanent right to use and modify his initial contribution as well as to publish it or its modified versions under the 3-clause BSD License.
The ClaRa development team consists of the following partners:
TLK-Thermo GmbH (Braunschweig, Germany)
XRG Simulation GmbH (Hamburg, Germany).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | k_FuelOvershoot | 100 | Gain of fuel overshoot |
| Real | eta_gen | 0.98 | Efficiency of generator |
| Part Load Definition | |||
| Real[:,:] | CL_Valve_ | [0, 0; 1, 1] | Characteristics of the turbine valve |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Blocks.Interfaces.RealInput | derP_max_ | Maximum overall power gradient | |
| Modelica.Blocks.Interfaces.RealInput | derP_StG_ | Maximum power gradient due to steam generator restrictions | |
| Modelica.Blocks.Interfaces.RealInput | derP_T_ | Maximum power gradient due to turbine restrictions | |
| Modelica.Blocks.Interfaces.RealInput | P_G_target_ | Target value generator power | |
| Modelica.Blocks.Interfaces.RealInput | P_max_ | Maximum generator power | |
| Modelica.Blocks.Interfaces.RealInput | P_min_ | Minimum generator power | |
| Modelica.Blocks.Interfaces.RealOutput | QF_FF_ | FiringPower feed forward | |
| Modelica.Blocks.Interfaces.RealOutput | y_Turbine_ | Feed forward value for turbine valve openeing | |
| Modelica.Blocks.Interfaces.RealOutput | P_G_set_ | Connector of Real output signal |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Blocks.Math.Min | min1 | ||
| Modelica.Blocks.Nonlinear.VariableLimiter | variableLimiter | ||
| Utilities.Blocks.VariableGradientLimiter | variableGradientLimiter | ||
| Modelica.Blocks.Math.Gain | gain | ||
| Modelica.Blocks.Math.Gain | FuelFeedForward | ||
| Modelica.Blocks.Continuous.Derivative | FuelOvershoot | ||
| Modelica.Blocks.Math.Add | add | ||
| Modelica.Blocks.Tables.CombiTable1Dv | turbineValveOpeneing | load dependend turbine valve opening |