modelCompressorGas_L1_simple

Simple compressor or fan for gas
Diagram of CompressorGas_L1_simple

Extends from ClaRa.Basics.Icons.Compressor.

Information

For detailed model documentation please consult the html-documentation shipped with ClaRa.

 


Authorship and Copyright Statement for original (initial) Contribution

Author:

DYNCAP/DYNSTART development team, Copyright © 2011-2024.

References:

For references please consult the html-documentation shipped with ClaRa.

Remarks:

This component was developed by ClaRa development team under the 3-clause BSD License.

Acknowledgements:

ClaRa originated from the collaborative research projects DYNCAP and DYNSTART. Both research projects were supported by the German Federal Ministry for Economic Affairs and Energy (FKZ 03ET2009 and FKZ 03ET7060).

CLA:

The author(s) have agreed to ClaRa CLA, version 1.0. See https://claralib.com/pdf/CLA.pdf

By agreeing to ClaRa CLA, version 1.0 the author has granted the ClaRa development team a permanent right to use and modify his initial contribution as well as to publish it or its modified versions under the 3-clause BSD License.

The ClaRa development team consists of the following partners:

TLK-Thermo GmbH (Braunschweig, Germany)

XRG Simulation GmbH (Hamburg, Germany).

Parameters

TypeNameDefaultDescription
Booleanallow_reverseFlowfalse
TILMedia.Gas.Types.BaseGasmediumsimCenter.flueGasModel
Realeta0.85isentropic efficiency
Summary and Visualisation
BooleancontributeToCycleSummarysimCenter.contributeToCycleSummaryTrue if component shall contribute to automatic efficiency calculation
General Settings
ClaRa.Components.TurboMachines.Compressors.Fundamentals.PresetVariableTypepresetVariableType"V_flow"Specifies which variable is preset
Mechanical shaft power
Booleanuse_P_shaftInputfalse= true, if P_shaft defined by input
Basics.Units.PowerP_shaft_fixed5e3Fixed value for mechanical shaft power
Pressure Increase
Booleanuse_Delta_p_inputfalse= true, if Delta_p defined by input
Basics.Units.PressureDelta_p_fixed0.1e5Fixed value for pressure increase
Mass Flow Rate
Booleanm_flowInputfalse= true, if m_flow defined by input
Basics.Units.MassFlowRatem_flow_fixed0.5Fixed value for gas mass flow rate
Volume Flow Rate
BooleanV_flowInputfalse= true, if V_flow defined by input
Basics.Units.VolumeFlowRateV_flow_fixed0.5e-3Fixed value for gas volume flow rate
Advanced
ClaRa.Basics.Units.TimeTau_aux0.1Time constant of auxilliary kappa states
Realkappa_initial1.3Initial value for kappas

Connectors

TypeNameDefaultDescription
ClaRa.Basics.Interfaces.GasPortIninletinlet flow
ClaRa.Basics.Interfaces.GasPortOutoutletoutlet flow
Modelica.Blocks.Interfaces.RealInputdp_inPrescribed pressure increase
Modelica.Blocks.Interfaces.RealInputP_shaft_inPrescribed pressure increase
Modelica.Blocks.Interfaces.RealInputV_flow_inPrescribed volume flow rate
Modelica.Blocks.Interfaces.RealInputm_flow_inPrescribed mass flow rate
Basics.Interfaces.EyeOutGaseyeOut

Components

TypeNameDefaultDescription
ClaRa.SimCentersimCenter
ClaRa.Basics.Interfaces.Connected2SimCenterconnected2SimCenter
TILMedia.Gas.Gas_pTflueGas_inlet
TILMedia.Gas.Gas_phflueGas_outlet
Realkappa
Realdeltah
RealhOut
RealkappaA
RealkappaB
RealkappaB_aux
RealkappaA_aux
Basics.Units.PressureDelta_ppressure increase
Basics.Units.PowerP_hydHydraulic power
Basics.Units.PowerP_shaftDrive power
Basics.Units.VolumeFlowRateV_flow
ClaRa.Components.TurboMachines.Compressors.Fundamentals.GetInputsHydraulicgetInputs
Summarysummary

Contents

NameDescription
Outline
Summary

Revisions

For revisions please consult the html-documentation shipped with ClaRa.