modelJoinVLE_L2_flex

A join for an arbitrary number of inputs
Diagram of JoinVLE_L2_flex

Extends from ClaRa.Basics.Icons.Adapter5_bw, ClaRa.Basics.Icons.ComplexityLevel (Displays the complexity level inside model icon ).

Information

For detailed model documentation please consult the html-documentation shipped with ClaRa.

 


Authorship and Copyright Statement for original (initial) Contribution

Author:

DYNCAP/DYNSTART development team, Copyright © 2011-2024.

References:

For references please consult the html-documentation shipped with ClaRa.

Remarks:

This component was developed by ClaRa development team under the 3-clause BSD License.

Acknowledgements:

ClaRa originated from the collaborative research projects DYNCAP and DYNSTART. Both research projects were supported by the German Federal Ministry for Economic Affairs and Energy (FKZ 03ET2009 and FKZ 03ET7060).

CLA:

The author(s) have agreed to ClaRa CLA, version 1.0. See https://claralib.com/pdf/CLA.pdf

By agreeing to ClaRa CLA, version 1.0 the author has granted the ClaRa development team a permanent right to use and modify his initial contribution as well as to publish it or its modified versions under the 3-clause BSD License.

The ClaRa development team consists of the following partners:

TLK-Thermo GmbH (Braunschweig, Germany)

XRG Simulation GmbH (Hamburg, Germany).

Parameters

TypeNameDefaultDescription
BooleanshowExpertSummaryfalse|Summary and Visualisation||True, if expert summary should be applied
BooleanshowDatatrue|Summary and Visualisation||True, if a data port containing p,T,h,s,m_flow shall be shown, else false
BooleanpreciseTwoPhasetrue|Expert Stettings||True, if two-phase transients should be capured precisely
Fundamental Definitions
TILMedia.VLEFluid.Types.BaseVLEFluidmediumsimCenter.fluid1Medium in the component
General › Fundamental Definitions
IntegerN_ports_in1Number of inlet ports
Initialisation
BooleanuseHomotopysimCenter.useHomotopyTrue, if homotopy method is used during initialisation
ClaRa.Basics.Units.EnthalpyMassSpecifich_start1e5Start value of sytsem specific enthalpy
ClaRa.Basics.Units.Pressurep_start1e5Start value of sytsem pressure
ClaRa.Basics.Units.MassFraction[medium.nc - 1]xi_startmedium.xi_default
IntegerinitOption0Type of initialisation
General › Geometry
ClaRa.Basics.Units.Volumevolume0.1System Volume
General › Nominal Values
ClaRa.Basics.Units.MassFlowRate[N_ports_in]m_flow_in_nom{10}Nominal mass flow rates at inlet
Nominal Values
ClaRa.Basics.Units.Pressurep_nom1e5Nominal pressure
ClaRa.Basics.Units.EnthalpyMassSpecifich_nom1e5Nominal specific enthalpy

Connectors

TypeNameDefaultDescription
ClaRa.Basics.Interfaces.FluidPortIn[N_ports_in]inletInlet port
ClaRa.Basics.Interfaces.FluidPortOutoutletOutlet port
ClaRa.Basics.Interfaces.EyeOuteye

Components

TypeNameDefaultDescription
Stringcomplexity (from ComplexityLevel)"??"
ClaRa.SimCentersimCenter
ClaRa.Basics.Units.EnthalpyFlowRate[N_ports_in]H_flow_in
ClaRa.Basics.Units.EnthalpyFlowRateH_flow_out
ClaRa.Basics.Units.EnthalpyMassSpecifich
ClaRa.Basics.Units.MassmassTotal system mass
Realdrhodt
ClaRa.Basics.Units.PressurepSystem pressure
ClaRa.Basics.Units.MassFlowRate[N_ports_in,medium.nc - 1]Xi_flow_inMass fraction flows at inlet
ClaRa.Basics.Units.MassFlowRate[medium.nc - 1]Xi_flow_outMass fraction flows at outlet
ClaRa.Basics.Units.MassFraction[medium.nc - 1]xiMass fraction
Summarysummary

Contents

NameDescription
Outline
Summary

Revisions

For revisions please consult the html-documentation shipped with ClaRa.