modelSplitVLE_L2_Y

A voluminous split for 2 outputs
Diagram of SplitVLE_L2_Y

Extends from ClaRa.Basics.Interfaces.DataInterfaceVector, ClaRa.Basics.Icons.Tpipe2, ClaRa.Basics.Icons.ComplexityLevel (Displays the complexity level inside model icon ).

Information

For detailed model documentation please consult the html-documentation shipped with ClaRa.

 


Authorship and Copyright Statement for original (initial) Contribution

Author:

DYNCAP/DYNSTART development team, Copyright © 2011-2024.

References:

For references please consult the html-documentation shipped with ClaRa.

Remarks:

This component was developed by ClaRa development team under the 3-clause BSD License.

Acknowledgements:

ClaRa originated from the collaborative research projects DYNCAP and DYNSTART. Both research projects were supported by the German Federal Ministry for Economic Affairs and Energy (FKZ 03ET2009 and FKZ 03ET7060).

CLA:

The author(s) have agreed to ClaRa CLA, version 1.0. See https://claralib.com/pdf/CLA.pdf

By agreeing to ClaRa CLA, version 1.0 the author has granted the ClaRa development team a permanent right to use and modify his initial contribution as well as to publish it or its modified versions under the 3-clause BSD License.

The ClaRa development team consists of the following partners:

TLK-Thermo GmbH (Braunschweig, Germany)

XRG Simulation GmbH (Hamburg, Germany).

Parameters

TypeNameDefaultDescription
BooleanshowExpertSummarysimCenter.showExpertSummary|Summary and Visualisation||True, if expert summary should be applied
BooleanshowDatatrue|Summary and Visualisation||True, if a data port containing p,T,h,s,m_flow shall be shown, else false
BooleanpreciseTwoPhasetrue|Expert Stettings||True, if two-phase transients should be capured precisely
Summary and Visualisation
IntegerN_sets (from DataInterfaceVector)0Number of data sets to be provided (if showData=true)
Fundamental Definitions
TILMedia.VLEFluid.Types.BaseVLEFluidmediumsimCenter.fluid1Medium in the component
Initialisation
BooleanuseHomotopysimCenter.useHomotopyTrue, if homotopy method is used during initialisation
Basics.Units.EnthalpyMassSpecifich_start1e5Start value of sytsem specific enthalpy
Basics.Units.Pressurep_start1e5Start value of sytsem pressure
ClaRa.Basics.Units.MassFraction[medium.nc - 1]xi_startmedium.xi_default
IntegerinitOption0Type of initialisation
General › Geometry
Basics.Units.Volumevolume0.1System Volume
General › Nominal Values
Basics.Units.MassFlowRate[2]m_flow_out_nom{10, 10}Nominal mass flow rates at outlet
Nominal Values
Basics.Units.Pressurep_nom1e5Nominal pressure
Basics.Units.EnthalpyMassSpecifich_nom1e5Nominal specific enthalpy

Connectors

TypeNameDefaultDescription
ClaRa.Basics.Interfaces.EyeOut[N_sets]eye (from DataInterfaceVector)
ClaRa.Basics.Interfaces.FluidPortIninletInlet port
ClaRa.Basics.Interfaces.FluidPortOutoutlet1Outlet port
ClaRa.Basics.Interfaces.FluidPortOutoutlet2Outlet port

Components

TypeNameDefaultDescription
Stringcomplexity (from ComplexityLevel)"??"
ClaRa.SimCentersimCenter
Basics.Units.EnthalpyFlowRateH_flow_in
Basics.Units.EnthalpyFlowRate[2]H_flow_out
Basics.Units.EnthalpyMassSpecifich
Basics.Units.MassmassTotal system mass
Realdrhodt
Basics.Units.PressurepSystem pressure
ClaRa.Basics.Units.MassFlowRate[medium.nc - 1]Xi_flow_inMass fraction flows at inlet
ClaRa.Basics.Units.MassFlowRate[2,medium.nc - 1]Xi_flow_outMass fraction flows at outlet
ClaRa.Basics.Units.MassFraction[medium.nc - 1]xiMass fraction
Summarysummary

Contents

NameDescription
Outline
Summary
PressureLossIn
PressureLossOut1
PressureLossOut2

Revisions

For revisions please consult the html-documentation shipped with ClaRa.