modelSprayInjectorVLE_L3

A spray injector for i.e. temperature control
Diagram of SprayInjectorVLE_L3

Extends from ClaRa.Basics.Icons.SprayInjector, ClaRa.Basics.Icons.ComplexityLevel (Displays the complexity level inside model icon ).

Information

For detailed model documentation please consult the html-documentation shipped with ClaRa.

 


Authorship and Copyright Statement for original (initial) Contribution

Author:

DYNCAP/DYNSTART development team, Copyright © 2011-2024.

References:

For references please consult the html-documentation shipped with ClaRa.

Remarks:

This component was developed by ClaRa development team under the 3-clause BSD License.

Acknowledgements:

ClaRa originated from the collaborative research projects DYNCAP and DYNSTART. Both research projects were supported by the German Federal Ministry for Economic Affairs and Energy (FKZ 03ET2009 and FKZ 03ET7060).

CLA:

The author(s) have agreed to ClaRa CLA, version 1.0. See https://claralib.com/pdf/CLA.pdf

By agreeing to ClaRa CLA, version 1.0 the author has granted the ClaRa development team a permanent right to use and modify his initial contribution as well as to publish it or its modified versions under the 3-clause BSD License.

The ClaRa development team consists of the following partners:

TLK-Thermo GmbH (Braunschweig, Germany)

XRG Simulation GmbH (Hamburg, Germany).

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.SpecificEnthalpyh_start_Main3000e3|Initialisation|Fluid|Initial specific enthalpy at main inlet
Modelica.Units.SI.SpecificEnthalpyh_start_Spray1000e3|Initialisation|Fluid|Initial specific enthalpy at main inlet
Modelica.Units.SI.Pressurep_start1e5|Initialisation|Fluid|Start value of sytsem pressure
BooleanuseHomotopysimCenter.useHomotopy|Initialisation||True, if homotopy method is used during initialisation
BooleanpreciseTwoPhasetrue|Expert Settings|Mixing Zone|True, if two-phase transients should be calculated precisely
BooleancheckValvefalse|Expert Settings|Injector Valve|True, if spray injector valve is check valve
BooleanuseStabilisedMassFlowfalse|Expert Settings|Injector Valve|True, if use pseudo state for mass flow in spray injector valve
RealTau0.001|Expert Settings|Injector Valve|Time constant of pseudo state in spray injector valve
Realopening_leak_0|Expert Settings|Injector Valve|Leakage valve opening in p.u.
IntegerN_wall3|Expert Settings|Wall|Number of radial elements of the wall
BooleanshowExpertSummarysimCenter.showExpertSummary|Summary and Visualisation||True, if expert summary should be applied
Fundamental Definitions
TILMedia.VLEFluid.Types.BaseVLEFluidmediumsimCenter.fluid1Medium in the component
Geometry
Modelica.Units.SI.Lengthdiameter_o0.5Diameter of the component
Modelica.Units.SI.Lengthdiameter_i0.45Diameter of the component
Modelica.Units.SI.Lengthlength3Length of the component
IntegerN1Number of identical injectors in parallel
Nominal Values
Modelica.Units.SI.Pressurep_nom1e5Nominal pressure
Modelica.Units.SI.SpecificEnthalpyh_nom_Main3000e3Nominal specific enthalpy
Modelica.Units.SI.SpecificEnthalpyh_nom_Spray1000e3Nominal specific enthalpy
Modelica.Units.SI.MassFlowRatem_flow_nom_main300Nominal mass flow rates at inlet
Modelica.Units.SI.PressureDelta_p_nom1000Nominal pressure loss
Modelica.Units.SI.MassFlowRatem_flow_nom_spray10Nominal injection mass flow rate
Initialisation › Fluid
IntegerinitOption0Type of initialisation
Summary and Visualisation
BooleanshowDatafalseTrue, if a data port containing p,T,h,s,m_flow shall be shown, else false

Connectors

TypeNameDefaultDescription
ClaRa.Basics.Interfaces.FluidPortIninlet1Inlet port
ClaRa.Basics.Interfaces.FluidPortIninlet2Inlet port
ClaRa.Basics.Interfaces.FluidPortOutoutletOutlet port
Modelica.Blocks.Interfaces.RealInputopening=1: completely open, =0: completely closed
ClaRa.Basics.Interfaces.EyeOuteye

Components

TypeNameDefaultDescription
Stringcomplexity (from ComplexityLevel)"??"
ClaRa.SimCentersimCenter
Summarysummary
ClaRa.Basics.ControlVolumes.FluidVolumes.VolumeVLE_L2outflowZone
ClaRa.Basics.ControlVolumes.SolidVolumes.CylindricalThickWall_L4wall
ClaRa.Components.VolumesValvesFittings.Valves.GenericValveVLE_L1valve
ClaRa.Components.VolumesValvesFittings.Fittings.JoinVLE_L2_YmixingZone

Contents

NameDescription
Outline
Wall_L4
Summary
Material
PressureLoss
HeatTransfer
PressureLoss_outflowZone
PressureLoss_mixingZoneInlet1
PressureLoss_mixingZoneInlet2
PressureLoss_mixingZoneOutlet

Revisions