modelThreeWayValveVLE_L2

A voluminous three way valve for VLE media
Diagram of ThreeWayValveVLE_L2

Extends from ClaRa.Components.VolumesValvesFittings.Valves.ThreeWayValve_base, ClaRa.Basics.Icons.ComplexityLevel (Displays the complexity level inside model icon ).

Information

For detailed model documentation please consult the html-documentation shipped with ClaRa.

 


Authorship and Copyright Statement for original (initial) Contribution

Author:

DYNCAP/DYNSTART development team, Copyright © 2011-2024.

References:

For references please consult the html-documentation shipped with ClaRa.

Remarks:

This component was developed by ClaRa development team under the 3-clause BSD License.

Acknowledgements:

ClaRa originated from the collaborative research projects DYNCAP and DYNSTART. Both research projects were supported by the German Federal Ministry for Economic Affairs and Energy (FKZ 03ET2009 and FKZ 03ET7060).

CLA:

The author(s) have agreed to ClaRa CLA, version 1.0. See https://claralib.com/pdf/CLA.pdf

By agreeing to ClaRa CLA, version 1.0 the author has granted the ClaRa development team a permanent right to use and modify his initial contribution as well as to publish it or its modified versions under the 3-clause BSD License.

The ClaRa development team consists of the following partners:

TLK-Thermo GmbH (Braunschweig, Germany)

XRG Simulation GmbH (Hamburg, Germany).

Parameters

TypeNameDefaultDescription
BooleanshowExpertSummary (from ThreeWayValve_base)simCenter.showExpertSummary|Summary and Visualisation||True, if expert summary should be applied
BooleanshowData (from ThreeWayValve_base)true|Summary and Visualisation||True, if a data port containing p,T,h,s,m_flow shall be shown, else false
BooleansplitRatio_input (from ThreeWayValve_base)false= true, if split ratio is defined by input
RealsplitRatio_fixed (from ThreeWayValve_base)0.5
BooleanpreciseTwoPhasetrue|Expert Settings||True, if two-phase transients should be capured precisely
Fundamental Definitions
TILMedia.VLEFluid.Types.BaseVLEFluidmedium (from ThreeWayValve_base)simCenter.fluid1Medium in the component
Initialisation
BooleanuseHomotopysimCenter.useHomotopyTrue, if homotopy method is used during initialisation
Basics.Units.EnthalpyMassSpecifich_start1e5Start value of sytsem specific enthalpy
Basics.Units.Pressurep_start1e5Start value of sytsem pressure
IntegerinitOption0Type of initialisation
General › Geometry
Basics.Units.Volumevolume0.1System Volume
General › Nominal Values
Basics.Units.MassFlowRate[2]m_flowOut_nom{10, 10}Nominal mass flow rates at outlet
Nominal Values
Basics.Units.Pressurep_nom1e5Nominal pressure
Basics.Units.EnthalpyMassSpecifich_nom1e5Nominal specific enthalpy

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInputsplitRatio_external (from ThreeWayValve_base)splitRatioControls mass fraction m2/m1
Basics.Interfaces.FluidPortIninlet (from ThreeWayValve_base)Inlet port
Basics.Interfaces.FluidPortOutoutlet1 (from ThreeWayValve_base)Outlet port
Basics.Interfaces.FluidPortOutoutlet2 (from ThreeWayValve_base)Outlet port
Basics.Interfaces.EyeOuteye1 (from ThreeWayValve_base)
Basics.Interfaces.EyeOuteye2 (from ThreeWayValve_base)

Components

TypeNameDefaultDescription
ClaRa.SimCentersimCenter (from ThreeWayValve_base)
RealsplitRatio (from ThreeWayValve_base)
Stringcomplexity (from ComplexityLevel)"??"
Basics.Units.EnthalpyFlowRateH_flow_in
Basics.Units.EnthalpyFlowRate[2]H_flow_out
Basics.Units.EnthalpyMassSpecifich
Basics.Units.MassmassTotal system mass
Realdrhodt
Basics.Units.PressurepSystem pressure
Summarysummary

Contents

NameDescription
Outline
Summary
PressureLoss

Revisions