modelIdealTransformerVariableTapI_INIT
Initialization for ideal transformer based on the network voltage and current
Extends from BaseClasses_INIT.BaseTransformerVariableTapCommon_INIT (Base model for initialization of transformers with variable tap), BaseClasses_INIT.BaseTransformerVariables_INIT (Base model for initialization of transformers), AdditionalIcons.Init.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Types.PerUnit | rTfoMinPu (from BaseTransformerVariableTapCommon_INIT) | Minimum transformation ratio in pu: U2/U1 in no load conditions | |
| Types.PerUnit | rTfoMaxPu (from BaseTransformerVariableTapCommon_INIT) | Maximum transformation ratio in pu: U2/U1 in no load conditions | |
| Integer | NbTap (from BaseTransformerVariableTapCommon_INIT) | Number of taps | |
| Types.VoltageModulePu | Uc20Pu (from BaseTransformerVariableTapCommon_INIT) | Voltage set-point on side 2 in pu (base U2Nom) |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Types.ComplexVoltagePu | u20Pu (from BaseTransformerVariableTapCommon_INIT) | Start value of complex voltage at terminal 2 in pu (base U2Nom) | |
| Types.ComplexCurrentPu | i20Pu (from BaseTransformerVariableTapCommon_INIT) | Start value of complex current at terminal 2 in pu (base U2Nom, SnRef) (receptor convention) | |
| Types.VoltageModulePu | U20Pu (from BaseTransformerVariableTapCommon_INIT) | Start value of voltage amplitude at terminal 2 in pu (base U2Nom) | |
| Integer | Tap0 (from BaseTransformerVariableTapCommon_INIT) | Start value of transformer tap | |
| Types.PerUnit | rTfo0Pu (from BaseTransformerVariableTapCommon_INIT) | Start value of transformer ratio | |
| Constants.state | state0 (from BaseTransformerVariableTapCommon_INIT) | Constants.state.Closed | Start value of connection state |
| Types.ComplexVoltagePu | u10Pu (from BaseTransformerVariables_INIT) | Start value of complex voltage at terminal 1 in pu (base UNom) | |
| Types.ComplexCurrentPu | i10Pu (from BaseTransformerVariables_INIT) | Start value of complex current at terminal 1 in pu (base UNom, SnRef) (receptor convention) | |
| Types.VoltageModulePu | U10Pu (from BaseTransformerVariables_INIT) | Start value of voltage amplitude at terminal 1 in pu (base U1Nom) | |
| Types.ActivePowerPu | P10Pu (from BaseTransformerVariables_INIT) | Start value of active power at terminal 1 in pu (base SnRef) (receptor convention) | |
| Types.ReactivePowerPu | Q10Pu (from BaseTransformerVariables_INIT) | Start value of reactive power at terminal 1 in pu (base SnRef) (receptor convention) |