| Integer | NbSwitchOffSignals (from SwitchOffLogic) | | Number of switch-off signals to take into account in inputs |
| Boolean | SwitchOffSignal10 (from SwitchOffLogic) | false | Initial switch-off signal 1 |
| Boolean | SwitchOffSignal20 (from SwitchOffLogic) | false | Initial switch-off signal 2 |
| Boolean | SwitchOffSignal30 (from SwitchOffLogic) | false | Initial switch-off signal 3 |
| Boolean | Running0 (from SwitchOffLogic) | if NbSwitchOffSignals >= 3 then not (SwitchOffSignal10 or SwitchOffSignal20 or SwitchOffSignal30) elseif NbSwitchOffSignals >= 2 then not (SwitchOffSignal10 or SwitchOffSignal20) else not SwitchOffSignal10 | Indicates if the component is initially running or not |
| Constants.state | State0 (from SwitchOffTransformer) | Constants.state.Closed | Start value of connection state |
| Types.ComplexVoltagePu | u10Pu | | Start value of complex voltage at terminal 1 (base U1Nom) |
| Types.ComplexCurrentPu | i10Pu | | Start value of complex current at terminal 1 (base U1Nom, SnRef) (receptor convention) |
| Types.ComplexVoltagePu | u20Pu | | Start value of complex voltage at terminal 2 (base U2Nom) |
| Types.ComplexCurrentPu | i20Pu | | Start value of complex current at terminal 2 (base U2Nom, SnRef) (receptor convention) |
| Types.VoltageModule | RatedU1 | | Rated voltage at terminal 1 in kV |
| Types.VoltageModule | RatedU2 | | Rated voltage at terminal 2 in kV |
| Types.VoltageModule | U1Nom | | Nominal voltage at terminal 1 in kV |
| Types.VoltageModule | U2Nom | | Nominal voltage at terminal 2 in kV |
| Types.PerUnit | rTfoPu | RatedU2/RatedU1*U1Nom/U2Nom | Transformation ratio in pu: U2/U1 in no load conditions |
| Modelica.SIunits.Resistance | R | | Resistance of the transformer in ohm |
| Modelica.SIunits.Reactance | X | | Reactance of the transformer in ohm |
| Modelica.SIunits.Conductance | G | | Conductance of the transformer in S |
| Modelica.SIunits.Susceptance | B | | Susceptance of the transformer in S |
| Modelica.SIunits.ComplexImpedance | Z | Complex(R, X) | Impedance of the transformer |
| Modelica.SIunits.ComplexAdmittance | Y | Complex(G, B) | Admittance of the transformer |
| Types.ComplexImpedancePu | ZPu | Complex(R/(U2Nom*U2Nom/SystemBase.SnRef), X/(U2Nom*U2Nom/SystemBase.SnRef)) | Impedance in pu (base U2Nom, SnRef) |
| Types.ComplexAdmittancePu | YPu | Complex(G*(U2Nom*U2Nom/SystemBase.SnRef), B*(U2Nom*U2Nom/SystemBase.SnRef)) | Admittance in pu (base U2Nom, SnRef) |
| Real | factorPuToASide1 | 1000.*SystemBase.SnRef/(sqrt(3.)*U1Nom) | |
| Real | factorPuToASide2 | 1000.*SystemBase.SnRef/(sqrt(3.)*U2Nom) | |