modelIEEE57BaseHvdcPs

Base class for IEEE 57-bus system benchmark formed with 57 buses, 7 generators, 3 shunts, 16 transformers, 1 phase shifter, 63 lines, 1 HVDC line and 42 loads

Extends from Dynawo.Examples.IEEE57.BaseClasses.IEEE57Base (Base class for IEEE 57-bus system benchmark formed with 57 buses, 7 generators, 3 shunts, 16 transformers, 63 lines and 42 loads).

Parameters

TypeNameDefaultDescription
Modelica.SIunits.ImpedanceZBASE69_0 (from IEEE57Base)69.0^2/SystemBase.SnRef
Modelica.SIunits.ImpedanceZBASE18_0 (from IEEE57Base)18.0^2/SystemBase.SnRef
Modelica.SIunits.ImpedanceZBASE13_8 (from IEEE57Base)13.8^2/SystemBase.SnRef
Realalpha (from IEEE57Base)1.5Active load sensitivity to voltage
Realbeta (from IEEE57Base)2.5Reactive load sensitivity to voltage
Types.VoltageModulePuuMaxPu (from IEEE57Base)1.15Maximum value of the voltage amplitude at terminal in pu (base UNom) that ensures the P/Q restoration
Types.VoltageModulePuuMinPu (from IEEE57Base)0.85Minimum value of the voltage amplitude at terminal in pu (base UNom) that ensures the P/Q restoration
Types.Timetfilter (from IEEE57Base)10

Components

TypeNameDefaultDescription
Dynawo.Electrical.Machines.SignalN.GeneratorPVGen1 (from IEEE57Base)
Dynawo.Electrical.Machines.SignalN.GeneratorPVGen2 (from IEEE57Base)
Dynawo.Electrical.Machines.SignalN.GeneratorPVGen3 (from IEEE57Base)
Dynawo.Electrical.Machines.SignalN.GeneratorPVGen6 (from IEEE57Base)
Dynawo.Electrical.Machines.SignalN.GeneratorPVGen8 (from IEEE57Base)
Dynawo.Electrical.Machines.SignalN.GeneratorPVGen9 (from IEEE57Base)
Dynawo.Electrical.Machines.SignalN.GeneratorPVGen12 (from IEEE57Base)
Dynawo.Electrical.Controls.Frequency.SignalNModelSignalN (from IEEE57Base)
Types.AngleTheta_Bus13 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad1 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad2 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad3 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad5 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad6 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad8 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad9 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad10 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad12 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad13 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad14 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad15 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad16 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad17 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad18 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad19 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad20 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad23 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad25 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad27 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad28 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad29 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad30 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad31 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad32 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad33 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad35 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad38 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad41 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad42 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad43 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad44 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad47 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad49 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad50 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad51 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad52 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad53 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad54 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad55 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad56 (from IEEE57Base)
Dynawo.Electrical.Loads.LoadAlphaBetaRestorativeLoad57 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus1 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus2 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus3 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus4 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus5 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus6 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus7 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus8 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus9 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus10 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus11 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus12 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus13 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus14 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus15 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus16 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus17 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus18 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus19 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus20 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus21 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus22 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus23 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus24 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus25 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus26 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus27 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus28 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus29 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus30 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus31 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus32 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus33 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus34 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus35 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus36 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus37 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus38 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus39 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus40 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus41 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus42 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus43 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus44 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus45 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus46 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus47 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus48 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus49 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus50 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus51 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus52 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus53 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus54 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus55 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus56 (from IEEE57Base)
Dynawo.Electrical.Buses.BusBus57 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB1B2 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB1B15 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB1B16 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB1B17 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB2B3 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB3B4 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB3B15 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB4B5 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB4B6 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB5B6 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB6B7 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB6B8 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB7B8 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB8B9 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB9B10 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB9B11 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB9B12 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB9B13 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB10B12 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB11B13 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB12B13 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB12B16 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB12B17 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB13B14 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB13B15 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB14B15 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB18B19 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB19B20 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB21B22 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB22B23 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB22B38 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB23B24 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB25B30 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB26B27 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB27B28 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB28B29 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB29B52 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB30B31 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB31B32 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB32B33 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB34B35 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB35B36 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB36B37 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB36B40 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB37B38 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB37B39 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB38B44 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB38B48 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB38B49 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB41B42 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB41B43 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB44B45 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB46B47 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB47B48 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB48B49 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB49B50 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB50B51 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB52B53 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB53B54 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB54B55 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB56B41 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB56B42 (from IEEE57Base)
Dynawo.Electrical.Lines.LineLineB57B56 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB10B51 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB13B49 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB14B46 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB15B45 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB21B20 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB24B26 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB24B25_1 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB24B25_2 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB34B32 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB39B57 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB40B56 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB9B55 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB4B18_1 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB4B18_2 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB11B43 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB11B41 (from IEEE57Base)
Dynawo.Electrical.Transformers.TransformerFixedRatioTfoB7B29 (from IEEE57Base)
Dynawo.Electrical.Shunts.ShuntBShunt18 (from IEEE57Base)
Dynawo.Electrical.Shunts.ShuntBShunt25 (from IEEE57Base)
Dynawo.Electrical.Shunts.ShuntBShunt53 (from IEEE57Base)
Dynawo.Electrical.HVDC.HvdcPV.HvdcPVHvdcLineB29B52
Dynawo.Electrical.HVDC.BaseControls.ACEmulationAcEmulation
Dynawo.Electrical.Controls.Transformers.PhaseShifterPPhaseShifterB7B29