recordIMC_withLosses

Machine parameters of indutction maschine with squirrel cage with losses

Extends from Modelica.Electrical.Machines.Utilities.ParameterRecords.IM_SquirrelCageData (Common parameters for induction machines with squirrel cage).

Parameters

TypeNameDefaultDescription
Integerm (from InductionMachineData)3Number of phases
SI.InertiaJr (from InductionMachineData)0.29Rotor's moment of inertia
SI.InertiaJs (from InductionMachineData)JrStator's moment of inertia
Integerp (from InductionMachineData)2Number of pole pairs (Integer)
SI.FrequencyfsNominal (from InductionMachineData)50Nominal frequency
RealeffectiveStatorTurns (from InductionMachineData)1Effective number of stator turns
Modelica.Units.SI.PowerPmNominal18500Nominal mechanical output power
Modelica.Units.SI.VoltageVsNominal400Nominal stator RMS voltage per phase
Modelica.Units.SI.CurrentIsNominal32.85Nominal stator RMS current per phase
RealpfsNominal0.898Nominal power factor
Modelica.Units.SI.PowerPsNominalsqrt(3)*VsNominal*IsNominal*pfsNominalNominal active stator power
Modelica.Units.SI.PowerlossNominalPsNominal - PmNominalNominal losses
RealeffNominal0.9049Nominal efficiency
Modelica.Units.SI.AngularVelocitywNominalModelica.Units.Conversions.from_rpm(1462.5)Nominal speed
Modelica.Units.SI.AngularVelocityw0Modelica.Units.Conversions.from_rpm(1499.64)No loads speed
Modelica.Units.SI.TorquetauNominalPmNominal/wNominalNominal torque
Modelica.Units.SI.TemperatureTNominalModelica.Units.Conversions.from_degC(90)Nominal temperature
Nominal resistances and inductances
SI.ResistanceRs (from InductionMachineData)0.03Stator resistance per phase at TRef
SI.TemperatureTsRef (from InductionMachineData)293.15Reference temperature of stator resistance
Machines.Thermal.LinearTemperatureCoefficient20alpha20s (from InductionMachineData)0Temperature coefficient of stator resistance at 20 degC
SI.InductanceLszero (from InductionMachineData)LssigmaStator zero sequence inductance
SI.InductanceLssigma (from InductionMachineData)3*(1 - sqrt(1 - 0.0667))/(2*pi*fsNominal)Stator stray inductance per phase
RealratioCommonStatorLeakage (from InductionMachineData)1Ratio of common stray inductance / total stray inductance of stator winding
SI.InductanceLm (from IM_SquirrelCageData)3*sqrt(1 - 0.0667)/(2*pi*fsNominal)Stator main field inductance per phase
SI.InductanceLrsigma (from IM_SquirrelCageData)3*(1 - sqrt(1 - 0.0667))/(2*pi*fsNominal)Rotor stray inductance per phase (equivalent three-phase winding)
SI.ResistanceRr (from IM_SquirrelCageData)0.04Rotor resistance per phase (equivalent three-phase winding) at TRef
SI.TemperatureTrRef (from IM_SquirrelCageData)293.15Reference temperature of rotor resistance
Machines.Thermal.LinearTemperatureCoefficient20alpha20r (from IM_SquirrelCageData)0Temperature coefficient of rotor resistance at 20 degC
Losses
Machines.Losses.FrictionParametersfrictionParameters (from InductionMachineData)Friction loss parameter record
Machines.Losses.CoreParametersstatorCoreParameters (from InductionMachineData)Stator core loss parameter record; all parameters refer to stator side
Machines.Losses.StrayLoadParametersstrayLoadParameters (from InductionMachineData)Stray load losses